Published 2001-04-25 · Federal Register document 01-10177
Airworthiness Directives; Boeing Model 737 Series Airplanes
Publication summary
This amendment adopts a new airworthiness directive (AD) that is applicable to all Boeing Model 737 series airplanes. This action requires revising the Airplane Flight Manual to prohibit extended dry operation of the center tank fuel pumps (with no fuel passing through the pumps). This action is necessary to prevent ignition of fuel vapors due to the generation of sparks and a potential ignition source inside the center tank caused by metal-to-metal contact during dry fuel pump operation, which could result in a fire or explosion of the fuel tank. This action is intended to address the identified unsafe condition.
Why this record is shown
Source: Federal Register annual FAA metadata. Acquired 2026-09-03T22:23:03.835669+00:00. The title, summary and date are source facts.
- Source revision
- federal_register_ad_metadata_2001-8d66ddb74aa17366
- Source row
- results[136]
- Raw source SHA-256
- 8d66ddb74aa17366596c5f6ccb4e6d04532df19ae027b6fa003379bdedb52c7e
Final-rule publication
Recorded publication clauses
- AD identifier printed in this edition
- 2001-08-24
- Effective date printed in this edition
- 2001-05-10
Some source clauses remain unstructured. Read the complete publication for conditions that have not been interpreted here.
Read 2 complete recorded clauses
Applicability wording · Applicability
Applicability: All Model 737 series airplanes, certificated in any category.
Exact source excerpt. Text positions 10167–10249, end exclusive, in the original decoded publication. SHA-256: a8ca96568836b0c8356bcbfdaadb60ee785ced60d9e8edd97eb729fbd1a0b1cf
Compliance and requirements
Compliance: Required as indicated, unless accomplished
previously.
To prevent ignition of fuel vapors due to the generation of
sparks and a potential ignition source inside the center tank caused
by metal-to-metal contact during dry fuel pump operation, which
could result in a fire or explosion of the fuel tank, accomplish the
following:
Revision of Airplane Flight Manual (AFM)
(a) Within 7 days after the effective date of this AD, revise
the Limitations Section of the FAA-approved AFM to include the
following information. This may be accomplished by inserting a copy
of this AD into the AFM.
``For ground operation, center tank fuel pump switches must not be
positioned to ``ON'' unless the center tank fuel quantity exceeds
1,000 pounds (453 kilograms), except when defueling or transferring
fuel.
Center tank fuel pump switches must be positioned to ``OFF'' when
both center tank fuel pump low pressure lights illuminate.
Center tank fuel pumps must not be ``ON'' unless personnel are
available in the flight deck to monitor low pressure lights.''
Alternative Methods of Compliance
(b) An alternative method of compliance or adjustment of the
compliance time that provides an acceptable level of safety may be
used if approved by the Manager, Seattle Aircraft Certification
Office (ACO), FAA. Operators shall submit their requests through an
appropriate FAA Principal Operations Inspector, who may add comments
and then send it to the Manager, Seattle ACO.
Note 1: Information concerning the existence of approved
alternative methods of compliance with this AD, if any, may be
obtained from the Seattle ACO.
Special Flight Permits
(c) Special flight permits may be issued in accordance with
sections 21.197 and 21.199 of the Federal Aviation Regulations (14
CFR 21.197 and 21.199) to operate the airplane to a location where
the requirements of this AD can be accomplished.
Effective Date
(d) This amendment becomes effective on May 10, 2001.
Exact source excerpt. Text positions 10249–12262, end exclusive, in the original decoded publication. SHA-256: b7beaa335cba175d89167589aef95033d92fc02b6b5215a49b25fe3d4ebab5eb
No replacement link has been established from this edition. The complete historical rule chain and current legal effect remain unknown.
Find all recorded historical references to AD 2001-08-24 · 0 printed reference observations in this pinned collection.
These are observations from one dated publication. Current legal status is unknown; aircraft applicability, installed configuration, compliance and burden require separate evidence. Missing or unparsed conditions remain unknown.
Why these observations are shown
They were extracted offline from the same immutable official HTML source as the complete recorded text. The dated source wording, original text coordinates and exact quote digests are retained. PDF/text agreement and current regulatory effect have not been qualified.
Observation revision: whole-ad-publication-clause-observations-1.0.1. Text SHA-256: f3b53998f2f5984e917cbdb7a5737d6ac1056dda14edf03a01b332a172835f74. Source manifest: 46e85eb98f88edff924bdd7f1a642a0ed53d24df0a67f9e7c0bf5d1a1ca54d2d.
Official source · 2001-04-25
Publication text
This is the complete recorded text of this dated publication.
Current legal effect is unknown. Aircraft applicability, installed configuration and compliance require separate evidence. PDF/text agreement has not been evaluated.
Read the complete official publication text
[Federal Register Volume 66, Number 80 (Wednesday, April 25, 2001)]
[Rules and Regulations]
[Pages 20733-20734]
From the Federal Register Online via the Government Publishing Office [www.gpo.gov]
[FR Doc No: 01-10177]
========================================================================
Rules and Regulations
Federal Register
________________________________________________________________________
This section of the FEDERAL REGISTER contains regulatory documents
having general applicability and legal effect, most of which are keyed
to and codified in the Code of Federal Regulations, which is published
under 50 titles pursuant to 44 U.S.C. 1510.
The Code of Federal Regulations is sold by the Superintendent of Documents.
Prices of new books are listed in the first FEDERAL REGISTER issue of each
week.
========================================================================
Federal Register / Vol. 66, No. 80 / Wednesday, April 25, 2001 /
Rules and Regulations
[[Page 20733]]
DEPARTMENT OF TRANSPORTATION
Federal Aviation Administration
14 CFR Part 39
[Docket No. 2001-NM-94-AD; Amendment 39-12201; AD 2001-08-24]
RIN 2120-AA64
Airworthiness Directives; Boeing Model 737 Series Airplanes
AGENCY: Federal Aviation Administration, DOT.
ACTION: Final rule; request for comments.
-----------------------------------------------------------------------
SUMMARY: This amendment adopts a new airworthiness directive (AD) that
is applicable to all Boeing Model 737 series airplanes. This action
requires revising the Airplane Flight Manual to prohibit extended dry
operation of the center tank fuel pumps (with no fuel passing through
the pumps). This action is necessary to prevent ignition of fuel vapors
due to the generation of sparks and a potential ignition source inside
the center tank caused by metal-to-metal contact during dry fuel pump
operation, which could result in a fire or explosion of the fuel tank.
This action is intended to address the identified unsafe condition.
DATES: Effective May 10, 2001.
Comments for inclusion in the Rules Docket must be received on or
before June 25, 2001.
ADDRESSES: Submit comments in triplicate to the Federal Aviation
Administration (FAA), Transport Airplane Directorate, ANM-114,
Attention: Rules Docket No. 2001-NM-94-AD, 1601 Lind Avenue, SW.,
Renton, Washington 98055-4056. Comments may be inspected at this
location between 9:00 a.m. and 3:00 p.m., Monday through Friday, except
Federal holidays. Comments may be submitted via fax to (425) 227-1232.
Comments may also be sent via the Internet using the following address:
[email protected]. Comments sent via fax or the Internet must
contain ``Docket No. 2001-NM-94-AD'' in the subject line and need not
be submitted in triplicate. Comments sent via the Internet as attached
electronic files must be formatted in Microsoft Word 97 for Windows or
ASCII text.
Information related to this AD may be examined at the FAA,
Transport Airplane Directorate, 1601 Lind Avenue, SW., Renton,
Washington.
FOR FURTHER INFORMATION CONTACT: Sherry Vevea, Aerospace Engineer,
Propulsion Branch, ANM-140S, FAA, Seattle Aircraft Certification
Office, 1601 Lind Avenue, SW., Renton, Washington 98055-4056; telephone
(425) 227-1360; fax (425) 227-1181.
SUPPLEMENTARY INFORMATION: On March 3, 2001, a Boeing Model 737-400
series airplane caught fire and burned while parked at a bay at the Don
Muang International Airport, Bangkok, Thailand. Although the accident
investigation is ongoing and the probable cause of the accident has not
been identified, the Government of Thailand, in conjunction with the
National Transportation Safety Board, has determined that the center
tank exploded shortly after the main fuel tanks of the airplane were
refueled. It appears that the center tank fuel pumps were operating dry
(no fuel was passing through the pumps) at the time of the explosion.
This accident is similar to the 1990 center tank explosion that
occurred on a Boeing Model 737-300 series airplane. The ignition source
of that explosion was never identified. The center tank fuel pumps were
operating dry at the time of that explosion.
Extended dry operation of the center tank fuel pumps, which had
occurred prior to both incidents, is contrary to the manufacturer's
procedures for safe operation of the fuel pumps. Extended dry pump
operation can result in overheating and excessive wear of the pump
bearings and consequent contact between rotating and nonrotating parts
of the pumps. Both overheating of the bearings and contact between
rotating and nonrotating parts have the potential to create an ignition
source in the form of hot surfaces or sparks. In addition, during dry
operation of the pumps, ignition of vapor in a fuel pump can create a
flame front that can reach the fuel tank and cause a fuel tank
explosion.
In light of this information, the FAA finds that certain procedures
should be included in the FAA-approved Airplane Flight Manual (AFM) for
Model 737 series airplanes to prohibit dry operation of center tank
fuel pumps. The FAA has determined that such procedures currently are
not defined adequately in the AFM for these airplanes.
Explanation of the Requirements of the Rule
Since an unsafe condition has been identified that is likely to
exist or develop on other airplanes of the same type design, this AD is
being issued to prevent ignition of fuel vapors due to the generation
of sparks and a potential ignition source inside the center tank caused
by metal-to-metal contact during dry fuel pump operation, which could
result in a fire or explosion of the fuel tank. This AD requires
revising the AFM to prohibit extended dry operation of the center tank
fuel pumps.
Interim Action
This is considered to be interim action until final action is
identified, at which time the FAA may consider further rulemaking.
Determination of Rule's Effective Date
Since a situation exists that requires the immediate adoption of
this regulation, it is found that notice and opportunity for prior
public comment hereon are impracticable, and that good cause exists for
making this amendment effective in less than 30 days.
Comments Invited
Although this action is in the form of a final rule that involves
requirements affecting flight safety and, thus, was not preceded by
notice and an opportunity for public comment, comments are invited on
this rule. Interested persons are invited to comment on this rule by
submitting such written data, views, or arguments as they may desire.
Communications shall identify the Rules Docket number and be submitted
in triplicate to the address specified under the caption ADDRESSES. All
communications received on or before the closing date for comments will
be considered, and this rule may be amended in light of the comments
[[Page 20734]]
received. Factual information that supports the commenter's ideas and
suggestions is extremely helpful in evaluating the effectiveness of the
AD action and determining whether additional rulemaking action would be
needed.
Submit comments using the following format:
<bullet> Organize comments issue-by-issue. For example, discuss a
request to change the compliance time and a request to change the
service bulletin reference as two separate issues.
<bullet> For each issue, state what specific change to the AD is
being requested.
<bullet> Include justification (e.g., reasons or data) for each
request.
Comments are specifically invited on the overall regulatory,
economic, environmental, and energy aspects of the rule that might
suggest a need to modify the rule. All comments submitted will be
available, both before and after the closing date for comments, in the
Rules Docket for examination by interested persons. A report that
summarizes each FAA-public contact concerned with the substance of this
AD will be filed in the Rules Docket.
Commenters wishing the FAA to acknowledge receipt of their comments
submitted in response to this rule must submit a self-addressed,
stamped postcard on which the following statement is made: ``Comments
to Docket No. 2001-NM-94-AD.'' The postcard will be date-stamped and
returned to the commenter.
Regulatory Impact
The regulations adopted herein will not have a substantial direct
effect on the States, on the relationship between the national
Government and the States, or on the distribution of power and
responsibilities among the various levels of government. Therefore, it
is determined that this final rule does not have federalism
implications under Executive Order 13132.
The FAA has determined that this regulation is an emergency
regulation that must be issued immediately to correct an unsafe
condition in aircraft, and that it is not a ``significant regulatory
action'' under Executive Order 12866. It has been determined further
that this action involves an emergency regulation under DOT Regulatory
Policies and Procedures (44 FR 11034, February 26, 1979). If it is
determined that this emergency regulation otherwise would be
significant under DOT Regulatory Policies and Procedures, a final
regulatory evaluation will be prepared and placed in the Rules Docket.
A copy of it, if filed, may be obtained from the Rules Docket at the
location provided under the caption ADDRESSES.
List of Subjects in 14 CFR Part 39
Air transportation, Aircraft, Aviation safety, Safety.
Adoption of the Amendment
Accordingly, pursuant to the authority delegated to me by the
Administrator, the Federal Aviation Administration amends part 39 of
the Federal Aviation Regulations (14 CFR part 39) as follows:
PART 39--AIRWORTHINESS DIRECTIVES
1. The authority citation for part 39 continues to read as follows:
Authority: 49 U.S.C. 106(g), 40113, 44701.
Sec. 39.13 [Amended]
2. Section 39.13 is amended by adding the following new
airworthiness directive:
2001-08-24 Boeing: Amendment 39-12201. Docket 2001-NM-94-AD.
Applicability: All Model 737 series airplanes, certificated in
any category.
Compliance: Required as indicated, unless accomplished
previously.
To prevent ignition of fuel vapors due to the generation of
sparks and a potential ignition source inside the center tank caused
by metal-to-metal contact during dry fuel pump operation, which
could result in a fire or explosion of the fuel tank, accomplish the
following:
Revision of Airplane Flight Manual (AFM)
(a) Within 7 days after the effective date of this AD, revise
the Limitations Section of the FAA-approved AFM to include the
following information. This may be accomplished by inserting a copy
of this AD into the AFM.
``For ground operation, center tank fuel pump switches must not be
positioned to ``ON'' unless the center tank fuel quantity exceeds
1,000 pounds (453 kilograms), except when defueling or transferring
fuel.
Center tank fuel pump switches must be positioned to ``OFF'' when
both center tank fuel pump low pressure lights illuminate.
Center tank fuel pumps must not be ``ON'' unless personnel are
available in the flight deck to monitor low pressure lights.''
Alternative Methods of Compliance
(b) An alternative method of compliance or adjustment of the
compliance time that provides an acceptable level of safety may be
used if approved by the Manager, Seattle Aircraft Certification
Office (ACO), FAA. Operators shall submit their requests through an
appropriate FAA Principal Operations Inspector, who may add comments
and then send it to the Manager, Seattle ACO.
Note 1: Information concerning the existence of approved
alternative methods of compliance with this AD, if any, may be
obtained from the Seattle ACO.
Special Flight Permits
(c) Special flight permits may be issued in accordance with
sections 21.197 and 21.199 of the Federal Aviation Regulations (14
CFR 21.197 and 21.199) to operate the airplane to a location where
the requirements of this AD can be accomplished.
Effective Date
(d) This amendment becomes effective on May 10, 2001.
Issued in Renton, Washington, on April 18, 2001.
Donald L. Riggin,
Acting Manager, Transport Airplane Directorate, Aircraft Certification
Service.
[FR Doc. 01-10177 Filed 4-24-01; 8:45 am]
BILLING CODE 4910-13-U
Why this text is shown
The complete text was extracted from the official GovInfo HTML edition for this publication. Acquired 2026-10-09T04:30:24.831375+00:00. Text extraction preserves the recorded source wording; it does not determine current requirements.
Open the captured official edition
- Source SHA-256
- 277ff0189f32d8098a495ae2964e7ed4c387e884b1f9f30bd36fe196c900da32
- Text SHA-256
- f3b53998f2f5984e917cbdb7a5737d6ac1056dda14edf03a01b332a172835f74
Return to the full metadata catalog · Search complete publication text · Explore retained publication text and evidence
Coverage and limits
These are dated publication metadata, recorded clauses and literal source observations. Word, model-label, header and reference matches do not establish current legal effect, manufacturer/model identity, aircraft applicability, installed configuration or compliance.
The collection uses 33 explicit annual source snapshots. Source captures and operative-text qualifications have separate states. Missing information remains unknown.