Back to publication catalog

Published 2004-06-02 · Federal Register document 04-11959

Airworthiness Directives; Raytheon Model BAe.125 Series 800A (Including C-29A and U-125 Variant) and 800B Airplanes; and Model Hawker 800 (Including U-125A Variant), and 800XP Airplanes

Publication summary

This amendment adopts a new airworthiness directive (AD), applicable to certain Raytheon Model BAe.125 series 800A (including C- 29A and U-125 variant) and 800B airplanes; and Model Hawker 800 (including U-125A variant) and 800XP airplanes; that requires a functional test of the engine fire extinguishing wiring for the appropriate installation; verification of the correct wiring connector installation; correction of wiring if necessary; and installation of new marker bands. This action is necessary to prevent incorrect wiring of the engine fire extinguisher bottles, which could result in one or both fire extinguisher bottles being discharged into the wrong engine nacelle. This action is intended to address the identified unsafe condition.

Why this record is shown

Source: Federal Register annual FAA metadata. Acquired 2026-09-03T22:23:13.905821+00:00. The title, summary and date are source facts.

Source revision
federal_register_ad_metadata_2004-cb1e1f18d61cac01
Source row
results[255]
Raw source SHA-256
cb1e1f18d61cac01616802134d899b0c8ce1a9f79716b5ee037f78e4cb53a00a

Final-rule publication

Recorded publication clauses

AD identifier printed in this edition
2004-11-01
Effective date printed in this edition
2004-07-07

Some source clauses remain unstructured. Read the complete publication for conditions that have not been interpreted here.

Read 2 complete recorded clauses
Applicability wording · Applicability
    Applicability: Model BAe.125 series 800A (including C-29A and U-
125 variant) and 800B airplanes; and Model Hawker 800 (including U-
125A variant) and 800XP airplanes; as listed in Raytheon Service 
Bulletin SB 26-3610, Revision 1, dated September 2003; certificated 
in any category.

Exact source excerpt. Text positions 6971–7260, end exclusive, in the original decoded publication. SHA-256: a22089db4864fd354f0b1c0700485cb595e0f06d29ed706851a22b60d3f158e3

Compliance and requirements
    Compliance: Required as indicated, unless accomplished 
previously.
    To prevent incorrect wiring of the engine fire extinguisher 
bottles, which could result in one or both fire extinguisher bottles 
being discharged into the wrong engine nacelle, accomplish the 
following:

Function Test, Verification, Installation, and Corrective Action

    (a) Within 70 flight hours or 30 days after the effective date 
of this AD, whichever occurs first, do the actions specified in 
paragraphs (a) (1) and (a) (2) of this AD per the Accomplishment 
Instructions of Raytheon Service Bulletin SB 26-3610, Revision 1, 
dated September 2003.
    (1) Perform a functional test of the engine fire extinguishing 
wiring for appropriate installation, and verify the correct wiring 
connector installation. If any connector is wired incorrectly, prior 
to further flight, correct the wiring.
    (2) Install the new marker bands.

Exception to Service Bulletin

    (b) Although the service bulletin referenced in this AD 
specifies to submit certain information to the manufacturer, this AD 
does not include such a requirement.

Alternative Methods of Compliance

    (c) In accordance with 14 CFR 39.19, the Manager, Wichita 
Aircraft Certification Office, FAA, is authorized to approve 
alternative methods of compliance for this AD.

Incorporation by Reference

    (d) The required actions shall be done in accordance with 
Raytheon Service Bulletin SB 26-3610, Revision 1, dated September 
2003. This incorporation by reference was approved by the Director 
of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR 
part 51. Copies may be obtained from Raytheon Aircraft Company, 
Department 62, P.O. Box 85, Wichita, Kansas 67201-0085. Copies may 
be inspected at the FAA, Transport Airplane Directorate, 1601 Lind 
Avenue, SW., Renton, Washington; or at the FAA, Wichita Aircraft 
Certification Office, 1801 Airport Road, Room 100, Mid-Continent 
Airport, Wichita, Kansas; or at the National Archives and Records 
Administration (NARA). For information on the availability of this 
material at NARA, call (202) 741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html.

Effective Date

    (e) This amendment becomes effective on July 7, 2004.

Exact source excerpt. Text positions 7260–9566, end exclusive, in the original decoded publication. SHA-256: 13b3548dcf1a86aaa89b0954c1ba01cadfb8e6c703f2f4c75adc816d2f1b5dd3

No replacement link has been established from this edition. The complete historical rule chain and current legal effect remain unknown.

Find all recorded historical references to AD 2004-11-01 · 0 printed reference observations in this pinned collection.

These are observations from one dated publication. Current legal status is unknown; aircraft applicability, installed configuration, compliance and burden require separate evidence. Missing or unparsed conditions remain unknown.

Why these observations are shown

They were extracted offline from the same immutable official HTML source as the complete recorded text. The dated source wording, original text coordinates and exact quote digests are retained. PDF/text agreement and current regulatory effect have not been qualified.

Observation revision: whole-ad-publication-clause-observations-1.0.1. Text SHA-256: 41fe965d81ef60f8dbe630201a03e061375ed9b5045663e760a5d720d2918fb4. Source manifest: b17695d361704a3b1416bad4c21549e11aec8f75f7a7bc7ebcd137091df80f10.

Official source · 2004-06-02

Publication text

This is the complete recorded text of this dated publication.

Current legal effect is unknown. Aircraft applicability, installed configuration and compliance require separate evidence. PDF/text agreement has not been evaluated.

Read the complete official publication text
[Federal Register Volume 69, Number 106 (Wednesday, June 2, 2004)]
[Rules and Regulations]
[Pages 30999-31000]
From the Federal Register Online via the Government Publishing Office [www.gpo.gov]
[FR Doc No: 04-11959]


=======================================================================
-----------------------------------------------------------------------

DEPARTMENT OF TRANSPORTATION

Federal Aviation Administration

14 CFR Part 39

[Docket No. 2003-NM-216-AD; Amendment 39-13646; AD 2004-11-01]
RIN 2120-AA64


Airworthiness Directives; Raytheon Model BAe.125 Series 800A 
(Including C-29A and U-125 Variant) and 800B Airplanes; and Model 
Hawker 800 (Including U-125A Variant), and 800XP Airplanes

AGENCY: Federal Aviation Administration, DOT.

ACTION: Final rule.

-----------------------------------------------------------------------

SUMMARY: This amendment adopts a new airworthiness directive (AD), 
applicable to certain Raytheon Model BAe.125 series 800A (including C-
29A and U-125 variant) and 800B airplanes; and Model Hawker 800 
(including U-125A variant) and 800XP airplanes; that requires a 
functional test of the engine fire extinguishing wiring for the 
appropriate installation; verification of the correct wiring connector 
installation; correction of wiring if necessary; and installation of 
new marker bands. This action is necessary to prevent incorrect wiring 
of the engine fire extinguisher bottles, which could result in one or 
both fire extinguisher bottles being discharged into the wrong engine 
nacelle. This action is intended to address the identified unsafe 
condition.

DATES: Effective July 7, 2004.
    The incorporation by reference of certain publications listed in 
the regulations is approved by the Director of the Federal Register as 
of July 7, 2004.

ADDRESSES: The service information referenced in this AD may be 
obtained from Raytheon Aircraft Company, Department 62, P.O. Box 85, 
Wichita, Kansas 67201-0085. This information may be examined at the 
Federal Aviation Administration (FAA), Transport Airplane Directorate, 
Rules Docket, 1601 Lind Avenue, SW., Renton, Washington; or at the FAA, 
Wichita Aircraft Certification Office, 1801 Airport Road, Room 100, 
Mid-Continent Airport, Wichita, Kansas; or at the National Archives and 
Records Administration (NARA). For information on the availability of 
this material at NARA, call (202) 741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html.

FOR FURTHER INFORMATION CONTACT: Jeff Pretz, Aerospace Engineer, 
Airframe and Propulsion Branch, ACE-118W, FAA, Wichita Aircraft 
Certification Office, 1801 Airport Road, Room 100, Mid-Continent 
Airport, Wichita, Kansas 67209; telephone (316) 946-4153; fax (316) 
946-4107.

SUPPLEMENTARY INFORMATION: A proposal to amend part 39 of the Federal 
Aviation Regulations (14 CFR part 39) to include an airworthiness 
directive (AD) that is applicable to certain Raytheon Model BAe.125 
series 800A (including C-29A and U-125 variant) and 800B airplanes; and 
Model Hawker 800 (including U-125A variant) and 800XP airplanes; was 
published in the Federal Register on February 26, 2004 (69 FR 8880). 
That action proposed to require a functional test of the engine fire 
extinguishing wiring for the appropriate installation; verification of 
the correct

[[Page 31000]]

wiring connector installation; correction of wiring if necessary; and 
installation of new marker bands.

Comments

    Interested persons have been afforded an opportunity to participate 
in the making of this amendment. No comments were submitted in response 
to the proposal or the FAA's determination of the cost to the public.

Conclusion

    The FAA has determined that air safety and the public interest 
require the adoption of the rule as proposed.

Cost Impact

    There are approximately 615 airplanes of the affected design in the 
worldwide fleet. The FAA estimates that 430 airplanes of U.S. registry 
will be affected by this AD, that it will take approximately 2 work 
hours per airplane to accomplish the required actions, and that the 
average labor rate is $65 per work hour. Required parts will cost 
approximately $20 per airplane. Based on these figures, the cost impact 
of the AD on U.S. operators is estimated to be $64,500, or $150 per 
airplane.
    The cost impact figure discussed above is based on assumptions that 
no operator has yet accomplished any of the requirements of this AD 
action, and that no operator would accomplish those actions in the 
future if this AD were not adopted. The cost impact figures discussed 
in AD rulemaking actions represent only the time necessary to perform 
the specific actions actually required by the AD. These figures 
typically do not include incidental costs, such as the time required to 
gain access and close up, planning time, or time necessitated by other 
administrative actions. The manufacturer may cover the cost of 
replacement parts associated with this proposed AD, subject to warranty 
conditions. Manufacturer warranty remedies may also be available for 
labor costs associated with this AD. As a result, the costs 
attributable to the AD may be less than stated above.

Regulatory Impact

    The regulations adopted herein will not have a substantial direct 
effect on the States, on the relationship between the national 
Government and the States, or on the distribution of power and 
responsibilities among the various levels of government. Therefore, it 
is determined that this final rule does not have federalism 
implications under Executive Order 13132.
    For the reasons discussed above, I certify that this action: (1) Is 
not a ``significant regulatory action'' under Executive Order 12866; 
(2) is not a ``significant rule'' under DOT Regulatory Policies and 
Procedures (44 FR 11034, February 26, 1979); and (3) will not have a 
significant economic impact, positive or negative, on a substantial 
number of small entities under the criteria of the Regulatory 
Flexibility Act. A final evaluation has been prepared for this action 
and it is contained in the Rules Docket. A copy of it may be obtained 
from the Rules Docket at the location provided under the caption 
ADDRESSES.

List of Subjects in 14 CFR Part 39

    Air transportation, Aircraft, Aviation safety, Incorporation by 
reference, Safety.

Adoption of the Amendment

0
Accordingly, pursuant to the authority delegated to me by the 
Administrator, the Federal Aviation Administration amends part 39 of 
the Federal Aviation Regulations (14 CFR part 39) as follows:

PART 39--AIRWORTHINESS DIRECTIVES

0
1. The authority citation for part 39 continues to read as follows:

    Authority: 49 U.S.C. 106(g), 40113, 44701.


Sec.  39.13  [Amended]

0
2. Section 39.13 is amended by adding the following new airworthiness 
directive:

2004-11-01 Raytheon Aircraft Company: Amendment 39-13646. Docket 
2003-NM-216-AD.

    Applicability: Model BAe.125 series 800A (including C-29A and U-
125 variant) and 800B airplanes; and Model Hawker 800 (including U-
125A variant) and 800XP airplanes; as listed in Raytheon Service 
Bulletin SB 26-3610, Revision 1, dated September 2003; certificated 
in any category.
    Compliance: Required as indicated, unless accomplished 
previously.
    To prevent incorrect wiring of the engine fire extinguisher 
bottles, which could result in one or both fire extinguisher bottles 
being discharged into the wrong engine nacelle, accomplish the 
following:

Function Test, Verification, Installation, and Corrective Action

    (a) Within 70 flight hours or 30 days after the effective date 
of this AD, whichever occurs first, do the actions specified in 
paragraphs (a) (1) and (a) (2) of this AD per the Accomplishment 
Instructions of Raytheon Service Bulletin SB 26-3610, Revision 1, 
dated September 2003.
    (1) Perform a functional test of the engine fire extinguishing 
wiring for appropriate installation, and verify the correct wiring 
connector installation. If any connector is wired incorrectly, prior 
to further flight, correct the wiring.
    (2) Install the new marker bands.

Exception to Service Bulletin

    (b) Although the service bulletin referenced in this AD 
specifies to submit certain information to the manufacturer, this AD 
does not include such a requirement.

Alternative Methods of Compliance

    (c) In accordance with 14 CFR 39.19, the Manager, Wichita 
Aircraft Certification Office, FAA, is authorized to approve 
alternative methods of compliance for this AD.

Incorporation by Reference

    (d) The required actions shall be done in accordance with 
Raytheon Service Bulletin SB 26-3610, Revision 1, dated September 
2003. This incorporation by reference was approved by the Director 
of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR 
part 51. Copies may be obtained from Raytheon Aircraft Company, 
Department 62, P.O. Box 85, Wichita, Kansas 67201-0085. Copies may 
be inspected at the FAA, Transport Airplane Directorate, 1601 Lind 
Avenue, SW., Renton, Washington; or at the FAA, Wichita Aircraft 
Certification Office, 1801 Airport Road, Room 100, Mid-Continent 
Airport, Wichita, Kansas; or at the National Archives and Records 
Administration (NARA). For information on the availability of this 
material at NARA, call (202) 741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html.

Effective Date

    (e) This amendment becomes effective on July 7, 2004.

    Issued in Renton, Washington, on May 17, 2004.
Kalene C. Yanamura,
Acting Manager, Transport Airplane Directorate, Aircraft Certification 
Service.

[FR Doc. 04-11959 Filed 6-1-04; 8:45 am]
BILLING CODE 4910-13-P


Why this text is shown

The complete text was extracted from the official GovInfo HTML edition for this publication. Acquired 2026-10-09T04:04:34.068243+00:00. Text extraction preserves the recorded source wording; it does not determine current requirements.

Open the captured official edition

Source SHA-256
dddb8b368549a89ed7f5304f77af0a44c4715cef69c8a41838a3e1c98a682f62
Text SHA-256
41fe965d81ef60f8dbe630201a03e061375ed9b5045663e760a5d720d2918fb4

Return to the full metadata catalog · Search complete publication text · Explore retained publication text and evidence

Coverage and limits

These are dated publication metadata, recorded clauses and literal source observations. Word, model-label, header and reference matches do not establish current legal effect, manufacturer/model identity, aircraft applicability, installed configuration or compliance.

The collection uses 33 explicit annual source snapshots. Source captures and operative-text qualifications have separate states. Missing information remains unknown.