Published 2005-04-27 · Federal Register document 05-8272
Airworthiness Directives; Raytheon Model Hawker 800XP Airplanes
Publication summary
The FAA is adopting a new airworthiness directive (AD) for certain Raytheon Model Hawker 800XP airplanes. This AD requires inspecting to detect damage of certain wiring in the flight compartment, performing corrective actions if necessary, modifying certain wiring connections, and revising the airplane flight manual. This AD is prompted by reports of miswiring in the power distribution system. We are issuing this AD to ensure that the flightcrew is aware of the source of battery power for certain equipment, and to prevent damage to wiring and surrounding equipment that could result in smoke or fire on the airplane.
Why this record is shown
Source: Federal Register annual FAA metadata. Acquired 2026-09-03T22:23:17.300228+00:00. The title, summary and date are source facts.
- Source revision
- federal_register_ad_metadata_2005-5d43d153038ee1c1
- Source row
- results[171]
- Raw source SHA-256
- 5d43d153038ee1c1c214f5c3688e38e25e37b832227fe65d52f7420a65ee20f2
Final-rule publication
Recorded publication clauses
- AD identifier printed in this edition
- 2005-09-03
- Effective date printed in this edition
- 2005-06-01
Read 10 complete recorded clauses
Effective Date
Effective Date
(a) This AD becomes effective June 1, 2005.
Exact source excerpt. Text positions 7594–7659, end exclusive, in the original decoded publication. SHA-256: 1f3e71c2dbf4d6a06387ac33fa360584ec08a23f76dee743d860214473321271
Affected ADs
Affected ADs
(b) None.
Exact source excerpt. Text positions 7659–7688, end exclusive, in the original decoded publication. SHA-256: 027fbc44617399472b6ac4741da3aee18448654374228bcf4fe3f01df6b1539b
Applicability wording · Applicability
Applicability
(c) This AD applies to Raytheon Model Hawker 800XP airplanes,
certificated in any category, serial numbers 258541, 258556, and
258567 through 258608 inclusive.
Exact source excerpt. Text positions 7688–7870, end exclusive, in the original decoded publication. SHA-256: 21f374170478cd8a613b5988353570a8348449afb0570e774810dc2fc8243ec0
Unsafe Condition
Unsafe Condition
(d) This AD was prompted by reports of miswiring in the power
distribution system. We are issuing this AD to ensure that the
flightcrew is aware of the source of battery power for certain
equipment, and to prevent damage to wiring and surrounding equipment
that could result in smoke or fire on the airplane.
Exact source excerpt. Text positions 7870–8206, end exclusive, in the original decoded publication. SHA-256: 66e01cc85c95116aaef4d375e46cf3f84d71b86f8f705da210053190dcc021a9
Compliance
Compliance
(e) You are responsible for having the actions required by this
AD performed within the compliance times specified, unless the
actions have already been done.
Exact source excerpt. Text positions 8206–8384, end exclusive, in the original decoded publication. SHA-256: 64a7a1579f37f56eafecd0aeb3c528e7c89f6292ed0cb53091423917642d5847
Service Information Reference
Service Information Reference
(f) The term ``service bulletin,'' as used in this AD, means
Raytheon Service Bulletin SB 24-3555, Revision 1, dated June 2004.
(1) Where the service bulletin specifies contacting the
manufacturer for information, this proposed AD requires, before
further flight, contacting the Manager, Wichita Aircraft
Certification Office (ACO), FAA. Then, before further flight, any
applicable action specified by the Manager, Wichita ACO, must be
accomplished in accordance with a method approved by the Manager,
Wichita ACO.
(2) The service bulletin also refers to Raytheon Hawker 800XP
Temporary Change P/N 140-590032-0005TC7, dated June 3, 2003, which
is intended to be inserted into the Emergency Procedures section of
the airplane flight manual to inform the flightcrew which standby
batteries provide power to what equipment once the actions in the
service bulletin have been done.
(3) Where the service bulletin specifies to report compliance
information to the manufacturer, this AD does not include that
requirement.
Exact source excerpt. Text positions 8384–9461, end exclusive, in the original decoded publication. SHA-256: 1b234ea89a03a167612f8711a5648bf1eaca651117da4f3c566d20684959368c
Inspection
Inspection
(g) Within 50 flight hours or 30 days after the effective date
of this AD, whichever is first: Perform a detailed inspection for
damage (primarily but not limited to evidence of heat damage) of
wiring in the
[[Page 21618]]
flight compartment, and all applicable corrective actions, by doing
all actions in Part 1 of the Accomplishment Instructions of the
service bulletin, except as provided by paragraphs (f)(1) and (f)(3)
of this AD. Any applicable corrective action must be done before
further flight.
Note 1: For the purposes of this AD, a detailed inspection is:
``An intensive examination of a specific item, installation, or
assembly to detect damage, failure, or irregularity. Available
lighting is normally supplemented with a direct source of good
lighting at an intensity deemed appropriate. Inspection aids such as
mirror, magnifying lenses, etc., may be necessary. Surface cleaning
and elaborate procedures may be required.''
Exact source excerpt. Text positions 9461–10438, end exclusive, in the original decoded publication. SHA-256: 93c086794608d903819b0c2af5734b3b12beb42adf82651189927a1a9f8463a2
Modification
Modification
(h) At the applicable time specified in paragraph (h)(1) or
(h)(2) of this AD, modify wiring in the flight compartment by doing
all actions in accordance with Part 2 of the Accomplishment
Instructions of the service bulletin. Following accomplishment of
the actions in Part 2 of the service bulletin, before further
flight, do all actions associated with the functional test,
including revising the Emergency Procedures section of the Raytheon
Hawker 800XP Airplane Flight Manual to include the information in
Temporary Change P/N 140-590032-0005TC7, in accordance with the
Accomplishment Instructions of the service bulletin.
(1) If no damage was found during the inspection required by
paragraph (g) of this AD: Do paragraph (h) within 300 flight hours
or 180 days after the effective date of this AD, whichever is first.
(2) If any damage is found during the inspection required by
paragraph (g) of this AD: Do paragraph (h) before further flight
after the damage is found.
Exact source excerpt. Text positions 10438–11455, end exclusive, in the original decoded publication. SHA-256: b926d2e998887d2dc1d24c137c4f4e4ca280875feb48f90bee82aae60e0f482f
Alternative Methods of Compliance (AMOCs)
Alternative Methods of Compliance (AMOCs)
(i) The Manager, Wichita ACO, has the authority to approve AMOCs
for this AD, if requested in accordance with the procedures found in
14 CFR 39.19.
Exact source excerpt. Text positions 11455–11653, end exclusive, in the original decoded publication. SHA-256: 76dbe015dc157d66d1a1f72f0de1ef773d0d1edbcb9b539d5c45d92a282765d7
Material Incorporated by Reference
Material Incorporated by Reference
(j) You must use Raytheon Service Bulletin SB 24-3555, Revision
1, dated June 2004, to perform the actions that are required by this
AD, unless the AD specifies otherwise. The Director of the Federal
Register approves the incorporation by reference of this document in
accordance with 5 U.S.C. 552(a) and 1 CFR part 51. For copies of the
service information, contact Raytheon Aircraft Company, Department
62, P.O. Box 85, Wichita, Kansas 67201-0085. To view the AD docket,
contact the Docket Management Facility, U.S. Department of
Transportation, 400 Seventh Street SW., room PL-401, Nassif
Building, Washington, DC. To review copies of the service
information, contact the National Archives and Records
Administration (NARA). For information on the availability of this
material at the NARA, call (202) 741-6030, or go to http://www.archives.gov/ federal--register/ code--of-- federal--
regulations/ ibr--locations.html.
Exact source excerpt. Text positions 11653–12628, end exclusive, in the original decoded publication. SHA-256: 108918031e615427b0b2429ec06572f16a494313b0ac1edfefe3ae082de6160f
No replacement link has been established from this edition. The complete historical rule chain and current legal effect remain unknown.
Find all recorded historical references to AD 2005-09-03 · 0 printed reference observations in this pinned collection.
These are observations from one dated publication. Current legal status is unknown; aircraft applicability, installed configuration, compliance and burden require separate evidence. Missing or unparsed conditions remain unknown.
Why these observations are shown
They were extracted offline from the same immutable official HTML source as the complete recorded text. The dated source wording, original text coordinates and exact quote digests are retained. PDF/text agreement and current regulatory effect have not been qualified.
Observation revision: whole-ad-publication-clause-observations-1.0.1. Text SHA-256: 5da490b76f13bd894b5fe97067b8a3f9c8e4debc607b0a3c8ec026a1835a286f. Source manifest: 0e28b7123b1a33969e48e1ea0db2d1ad91e7bbfa4b60c92484f17217832ea781.
Official source · 2005-04-27
Publication text
This is the complete recorded text of this dated publication.
Current legal effect is unknown. Aircraft applicability, installed configuration and compliance require separate evidence. PDF/text agreement has not been evaluated.
Read the complete official publication text
[Federal Register Volume 70, Number 80 (Wednesday, April 27, 2005)]
[Rules and Regulations]
[Pages 21616-21618]
From the Federal Register Online via the Government Publishing Office [www.gpo.gov]
[FR Doc No: 05-8272]
=======================================================================
-----------------------------------------------------------------------
DEPARTMENT OF TRANSPORTATION
Federal Aviation Administration
14 CFR Part 39
[Docket No. FAA-2005-20251; Directorate Identifier 2004-NM-164-AD;
Amendment 39-14071; AD 2005-09-03]
RIN 2120-AA64
Airworthiness Directives; Raytheon Model Hawker 800XP Airplanes
AGENCY: Federal Aviation Administration (FAA), Department of
Transportation (DOT).
ACTION: Final rule.
-----------------------------------------------------------------------
SUMMARY: The FAA is adopting a new airworthiness directive (AD) for
certain Raytheon Model Hawker 800XP airplanes. This AD requires
inspecting to detect damage of certain wiring in the flight
compartment, performing corrective actions if necessary, modifying
certain wiring connections, and revising the airplane flight manual.
This AD is prompted by reports of miswiring in the power distribution
system. We are issuing this AD to ensure that the flightcrew is aware
of the source of battery power for certain equipment, and to prevent
damage to wiring and surrounding equipment that could result in smoke
or fire on the airplane.
DATES: This AD becomes effective June 1, 2005.
The incorporation by reference of certain publications listed in
the AD is approved by the Director of the Federal Register as of June
1, 2005.
ADDRESSES: For service information identified in this AD, contact
Raytheon Aircraft Company, Department 62, P.O. Box 85, Wichita, Kansas
67201-0085.
Docket: The AD docket contains the proposed AD, comments, and any
final disposition. You can examine the AD docket on the Internet at
http://dms.dot.gov, or in person at the Docket Management Facility
office between 9 a.m. and 5 p.m., Monday through Friday, except Federal
holidays. The Docket Management Facility office (telephone (800) 647-
5227) is located on the plaza level of the Nassif Building at the U.S.
Department of Transportation, 400 Seventh Street, SW., room PL-401,
Washington, DC. This docket number is FAA-2005-20251; the directorate
identifier for this docket is 2004-NM-164-AD.
FOR FURTHER INFORMATION CONTACT: Philip Petty, Aerospace Engineer,
Electrical Systems and Avionics, ACE-119W, FAA, Wichita Aircraft
Certification Office, 1801 Airport Road,
[[Page 21617]]
room 100, Mid-Continent Airport, Wichita, Kansas 67209; telephone (316)
946-4139; fax (316) 946-4107.
SUPPLEMENTARY INFORMATION: The FAA proposed to amend 14 CFR Part 39
with an AD for certain Raytheon Model Hawker 800XP airplanes. That
action, published in the Federal Register on February 2, 2005 (70 FR
5387), proposed to require inspecting to detect damage of certain
wiring in the flight compartment, performing corrective actions if
necessary, modifying certain wiring connections, and revising the
airplane flight manual.
Comments
We provided the public the opportunity to participate in the
development of this AD. No comments have been submitted on the proposed
AD or on the determination of the cost to the public.
Conclusion
We have carefully reviewed the available data and determined that
air safety and the public interest require adopting the AD as proposed.
Costs of Compliance
There are about 45 airplanes of the affected design in the
worldwide fleet. The following table provides the estimated costs for
U.S. operators to comply with this AD.
Estimated Costs
--------------------------------------------------------------------------------------------------------------------------------------------------------
Number of
Average Cost per U.S. -
Action Work hours labor rate Parts airplane registered Fleet cost
per hour airplanes
--------------------------------------------------------------------------------------------------------------------------------------------------------
Inspection..................................... 18 $65 None............................ $1,170 30 $35,100
Modification................................... 6 65 435............................. 825 30 24,750
--------------------------------------------------------------------------------------------------------------------------------------------------------
Authority for This Rulemaking
Title 49 of the United States Code specifies the FAA's authority to
issue rules on aviation safety. Subtitle I, Section 106, describes the
authority of the FAA Administrator. Subtitle VII, Aviation Programs,
describes in more detail the scope of the Agency's authority.
We are issuing this rulemaking under the authority described in
Subtitle VII, Part A, Subpart III, Section 44701, ``General
requirements.'' Under that section, Congress charges the FAA with
promoting safe flight of civil aircraft in air commerce by prescribing
regulations for practices, methods, and procedures the Administrator
finds necessary for safety in air commerce. This regulation is within
the scope of that authority because it addresses an unsafe condition
that is likely to exist or develop on products identified in this
rulemaking action.
Regulatory Findings
We have determined that this AD will not have federalism
implications under Executive Order 13132. This AD will not have a
substantial direct effect on the States, on the relationship between
the national government and the States, or on the distribution of power
and responsibilities among the various levels of government.
For the reasons discussed above, I certify that this AD:
(1) Is not a ``significant regulatory action'' under Executive
Order 12866;
(2) Is not a ``significant rule'' under DOT Regulatory Policies and
Procedures (44 FR 11034, February 26, 1979); and
(3) Will not have a significant economic impact, positive or
negative, on a substantial number of small entities under the criteria
of the Regulatory Flexibility Act.
We prepared a regulatory evaluation of the estimated costs to
comply with this AD. See the ADDRESSES section for a location to
examine the regulatory evaluation.
List of Subjects in 14 CFR Part 39
Air transportation, Aircraft, Aviation safety, Incorporation by
reference, Safety.
Adoption of the Amendment
0
Accordingly, under the authority delegated to me by the Administrator,
the FAA amends 14 CFR part 39 as follows:
PART 39--AIRWORTHINESS DIRECTIVES
0
1. The authority citation for part 39 continues to read as follows:
Authority: 49 U.S.C. 106(g), 40113, 44701.
Sec. 39.13 [Amended]
0
2. The FAA amends Sec. 39.13 by adding the following new airworthiness
directive (AD):
2005-09-03 Raytheon Aircraft Company: Amendment 39-14071. Docket No.
FAA-2005-20251; Directorate Identifier 2004-NM-164-AD.
Effective Date
(a) This AD becomes effective June 1, 2005.
Affected ADs
(b) None.
Applicability
(c) This AD applies to Raytheon Model Hawker 800XP airplanes,
certificated in any category, serial numbers 258541, 258556, and
258567 through 258608 inclusive.
Unsafe Condition
(d) This AD was prompted by reports of miswiring in the power
distribution system. We are issuing this AD to ensure that the
flightcrew is aware of the source of battery power for certain
equipment, and to prevent damage to wiring and surrounding equipment
that could result in smoke or fire on the airplane.
Compliance
(e) You are responsible for having the actions required by this
AD performed within the compliance times specified, unless the
actions have already been done.
Service Information Reference
(f) The term ``service bulletin,'' as used in this AD, means
Raytheon Service Bulletin SB 24-3555, Revision 1, dated June 2004.
(1) Where the service bulletin specifies contacting the
manufacturer for information, this proposed AD requires, before
further flight, contacting the Manager, Wichita Aircraft
Certification Office (ACO), FAA. Then, before further flight, any
applicable action specified by the Manager, Wichita ACO, must be
accomplished in accordance with a method approved by the Manager,
Wichita ACO.
(2) The service bulletin also refers to Raytheon Hawker 800XP
Temporary Change P/N 140-590032-0005TC7, dated June 3, 2003, which
is intended to be inserted into the Emergency Procedures section of
the airplane flight manual to inform the flightcrew which standby
batteries provide power to what equipment once the actions in the
service bulletin have been done.
(3) Where the service bulletin specifies to report compliance
information to the manufacturer, this AD does not include that
requirement.
Inspection
(g) Within 50 flight hours or 30 days after the effective date
of this AD, whichever is first: Perform a detailed inspection for
damage (primarily but not limited to evidence of heat damage) of
wiring in the
[[Page 21618]]
flight compartment, and all applicable corrective actions, by doing
all actions in Part 1 of the Accomplishment Instructions of the
service bulletin, except as provided by paragraphs (f)(1) and (f)(3)
of this AD. Any applicable corrective action must be done before
further flight.
Note 1: For the purposes of this AD, a detailed inspection is:
``An intensive examination of a specific item, installation, or
assembly to detect damage, failure, or irregularity. Available
lighting is normally supplemented with a direct source of good
lighting at an intensity deemed appropriate. Inspection aids such as
mirror, magnifying lenses, etc., may be necessary. Surface cleaning
and elaborate procedures may be required.''
Modification
(h) At the applicable time specified in paragraph (h)(1) or
(h)(2) of this AD, modify wiring in the flight compartment by doing
all actions in accordance with Part 2 of the Accomplishment
Instructions of the service bulletin. Following accomplishment of
the actions in Part 2 of the service bulletin, before further
flight, do all actions associated with the functional test,
including revising the Emergency Procedures section of the Raytheon
Hawker 800XP Airplane Flight Manual to include the information in
Temporary Change P/N 140-590032-0005TC7, in accordance with the
Accomplishment Instructions of the service bulletin.
(1) If no damage was found during the inspection required by
paragraph (g) of this AD: Do paragraph (h) within 300 flight hours
or 180 days after the effective date of this AD, whichever is first.
(2) If any damage is found during the inspection required by
paragraph (g) of this AD: Do paragraph (h) before further flight
after the damage is found.
Alternative Methods of Compliance (AMOCs)
(i) The Manager, Wichita ACO, has the authority to approve AMOCs
for this AD, if requested in accordance with the procedures found in
14 CFR 39.19.
Material Incorporated by Reference
(j) You must use Raytheon Service Bulletin SB 24-3555, Revision
1, dated June 2004, to perform the actions that are required by this
AD, unless the AD specifies otherwise. The Director of the Federal
Register approves the incorporation by reference of this document in
accordance with 5 U.S.C. 552(a) and 1 CFR part 51. For copies of the
service information, contact Raytheon Aircraft Company, Department
62, P.O. Box 85, Wichita, Kansas 67201-0085. To view the AD docket,
contact the Docket Management Facility, U.S. Department of
Transportation, 400 Seventh Street SW., room PL-401, Nassif
Building, Washington, DC. To review copies of the service
information, contact the National Archives and Records
Administration (NARA). For information on the availability of this
material at the NARA, call (202) 741-6030, or go to http://www.archives.gov/ federal--register/ code--of-- federal--
regulations/ ibr--locations.html.
Issued in Renton, Washington, on April 18, 2005.
Ali Bahrami,
Manager, Transport Airplane Directorate, Aircraft Certification
Service.
[FR Doc. 05-8272 Filed 4-26-05; 8:45 am]
BILLING CODE 4910-13-P
Why this text is shown
The complete text was extracted from the official GovInfo HTML edition for this publication. Acquired 2026-10-09T03:55:45.574318+00:00. Text extraction preserves the recorded source wording; it does not determine current requirements.
Open the captured official edition
- Source SHA-256
- d8d19d66786e3723680ed943a82a38159a398ffaf3d4baedce2797cba8de0277
- Text SHA-256
- 5da490b76f13bd894b5fe97067b8a3f9c8e4debc607b0a3c8ec026a1835a286f
Return to the full metadata catalog · Search complete publication text · Explore retained publication text and evidence
Coverage and limits
These are dated publication metadata, recorded clauses and literal source observations. Word, model-label, header and reference matches do not establish current legal effect, manufacturer/model identity, aircraft applicability, installed configuration or compliance.
The collection uses 33 explicit annual source snapshots. Source captures and operative-text qualifications have separate states. Missing information remains unknown.