Published 2014-09-15 · Federal Register document 2014-21770
Airworthiness Directives; Bombardier, Inc. Airplanes
Publication summary
We are adopting a new airworthiness directive (AD) for certain Bombardier, Inc. Model DHC-8-102, -103, -106, -201, -202, -301, -311, and --315 airplanes. This AD was prompted by reports of dual alternating current (AC) generator failure during flight. The failure was attributed to wire chafing along the wing lower flap shroud. This AD requires revising the maintenance program to incorporate certain tasks for the electrical wiring interconnection system inspection program. We are issuing this AD to prevent failure of both AC generators due to wire chafing, which could result in loss of power to the anti-icing heaters for the elevator horn, engine inlet, and propeller, and consequent ice accumulation in these areas, which could adversely affect the controllability of the airplane.
Why this record is shown
Source: Federal Register annual FAA metadata. Acquired 2026-09-03T22:23:45.694519+00:00. The title, summary and date are source facts.
- Source revision
- federal_register_ad_metadata_2014-642efe379108139d
- Source row
- results[263]
- Raw source SHA-256
- 642efe379108139d70cbf0492188bfdaee07f4da1173b6bc01335f4de404a707
Final-rule publication
Recorded publication clauses
- AD identifier printed in this edition
- 2013-15-06
- Effective date printed in this edition
- 2014-10-20
Read 12 complete recorded clauses
Effective Date
(a) Effective Date
This airworthiness directive (AD) becomes effective October 20,
2014.
Exact source excerpt. Text positions 13076–13172, end exclusive, in the original decoded publication. SHA-256: 75bba0c3b61fe614b30df93fe9337adcd076539020027bf04a57d1e46d16d798
Affected ADs
(b) Affected ADs
None.
Exact source excerpt. Text positions 13172–13201, end exclusive, in the original decoded publication. SHA-256: 871a4afc60ceeae06e8010585055188633d616078500c45937092bfe892239c0
Applicability wording · Applicability
(c) Applicability
This AD applies to Bombardier, Inc. Model DHC-8-102, -103, -106,
-201, -202, -301, -311, and -315 airplanes, certificated in any
category, serial numbers 003 and subsequent.
Exact source excerpt. Text positions 13201–13401, end exclusive, in the original decoded publication. SHA-256: 49628a898634abf142561af192300a6e0a1541ef26f74910799176c0cc5d144f
Subject
(d) Subject
Air Transport Association (ATA) of America Code 24, Electrical
Power.
Exact source excerpt. Text positions 13401–13490, end exclusive, in the original decoded publication. SHA-256: 2f211054234f9b656c228d5ed94963145e66d980d580552d614fd425d6f5b15a
Reason
(e) Reason
This AD was prompted by reports of dual alternating current (AC)
generator failure during flight. The failure was attributed to wire
chafing along the wing lower flap shroud. We are issuing this AD to
prevent failure of both AC generators due to wire chafing, which
could result in loss of power to the anti-icing heaters for the
elevator horn, engine inlet, and propeller, and consequent ice
accumulation in these areas, which could adversely affect the
controllability of the airplane.
[[Page 54893]]
Exact source excerpt. Text positions 13490–14018, end exclusive, in the original decoded publication. SHA-256: 79f55f4eb08d863d892b4e2b3ec0e1e3fc36b1c9f950f67009a0494b22da961b
Compliance
(f) Compliance
Comply with this AD within the compliance times specified,
unless already done.
Exact source excerpt. Text positions 14018–14120, end exclusive, in the original decoded publication. SHA-256: 00fbfa31932483f627d0ce0a11cbd2e35e15d9231842b91ac85623ce533912d3
Revision of Maintenance or Inspection Program
(g) Revision of Maintenance or Inspection Program
Within 30 days after the effective date of this AD: Incorporate
tasks for performing a general visual inspection of the wiring and
associated electrical wiring interconnection system (EWIS)
components into the airplane maintenance or inspection program, as
applicable, in accordance with a method approved by the Manager, New
York Aircraft Certification Office (ACO), ANE-170, FAA.
Note 1 to paragraph (g) of this AD: For Model DHC-8-100 series
airplanes, the instructions provided in de Havilland Dash 8
Maintenance Task Cards 531X1 and 631X1, ``General visual inspection
of the wiring and associated electrical wiring interconnection
system (EWIS) components,'' in Section 8, ``Electrical Wiring
Interconnection System Inspection Program,'' of the Bombardier (de
Havilland) Dash 8 Series 100 Maintenance Review Board Report of the
Bombardier (de Havilland) Dash 8 Series 100 Maintenance Program
Manual PSM 1-8-7, Revision 25, dated February 20, 2012, provides
guidance for revising the maintenance program to include general
visual inspections of the wiring and associated EWIS components.
This service information is not incorporated by reference in this
AD.
Note 2 to paragraph (g) of this AD: For Model DHC-8-200 series
airplanes, the instructions provided in de Havilland Dash 8
Maintenance Task Cards 531X1 and 631X1, ``General visual inspection
of the wiring and associated electrical wiring interconnection
system (EWIS) components,'' in Section 8, ``Electrical Wiring
Interconnection System Inspection Program,'' of the Bombardier (de
Havilland) Dash 8 Series 200 Maintenance Review Board Report of the
Bombardier (de Havilland) Dash 8 Series 200 Maintenance Program
Manual PSM 1-82-7, Revision 16, dated February 20, 2012, provides
guidance for revising the maintenance program to include general
visual inspections of the wiring and associated EWIS components.
This service information is not incorporated by reference in this
AD.
Note 3 to paragraph (g) of this AD: For Model DHC-8-300 series
airplanes, the instructions provided in de Havilland Dash 8
Maintenance Task Cards 531X1 and 631X1, ``General visual inspection
of the wiring and associated electrical wiring interconnection
system (EWIS) components,'' in Section 8, ``Electrical Wiring
Interconnection System Inspection Program,'' of the Bombardier (de
Havilland) Dash 8 Series 300 Maintenance Review Board Report of the
Bombardier (de Havilland) Dash 8 Series 300 Bombardier Maintenance
Program Manual PSM 1-83-7, Revision 25, dated February 20, 2012,
provides guidance for revising the maintenance program to include
general visual inspections of the wiring and associated EWIS
components. This service information is not incorporated by
reference in this AD.
Exact source excerpt. Text positions 14120–16964, end exclusive, in the original decoded publication. SHA-256: 5ea86aa22f940f3fba536d1422cf789ab03b9b80870c78b0ca7365a87438f5ed
Initial Task Compliance Time
(h) Initial Task Compliance Time
The initial compliance time for the tasks incorporated into the
maintenance or inspection program, as applicable, specified in
paragraph (g) of this AD, is at the applicable time specified in
paragraph (h)(1) or (h)(2) of this AD.
(1) For airplanes with 45,000 total flight hours or more as of
the effective date of this AD: Within 1,000 flight hours after the
effective date of this AD.
(2) For airplanes with less than 45,000 total flight hours as of
the effective date of this AD: Within 6,000 flight hours after the
effective date of this AD, but not to exceed 46,000 total flight
hours.
Exact source excerpt. Text positions 16964–17611, end exclusive, in the original decoded publication. SHA-256: 16de507aa44cf65b91090ce4a7703435a6dfae0952b5787b93005811995f18f0
No Alternative Actions or Intervals
(i) No Alternative Actions or Intervals
After accomplishing the revisions required by paragraph (g) of
this AD, no alternative actions (e.g., inspections) or intervals may
be used, unless the actions and intervals are approved as an
alternative method of compliance (AMOC) in accordance with the
procedures specified in paragraph (j)(1) of this AD.
Exact source excerpt. Text positions 17611–17970, end exclusive, in the original decoded publication. SHA-256: 1dabdeff7a54dfc52e6fbc15fa3367f0f4f62983b53db65b0ad567ef11be7fe9
Other FAA AD Provisions
(j) Other FAA AD Provisions
The following provisions also apply to this AD:
(1) Alternative Methods of Compliance (AMOCs): The Manager, New
York ACO, ANE-170, FAA, has the authority to approve AMOCs for this
AD, if requested using the procedures found in 14 CFR 39.19. In
accordance with 14 CFR 39.19, send your request to your principal
inspector or local Flight Standards District Office, as appropriate.
If sending information directly to the ACO, send it to ATTN: Program
Manager, Continuing Operational Safety, FAA, New York ACO, 1600
Stewart Avenue, Suite 410, Westbury, NY 11590; telephone 516-228-
7300; fax 516-794-5531. Before using any approved AMOC, notify your
appropriate principal inspector, or lacking a principal inspector,
the manager of the local flight standards district office/
certificate holding district office. The AMOC approval letter must
specifically reference this AD.
(2) Contacting the Manufacturer: For any requirement in this AD
to obtain corrective actions from a manufacturer, the action must be
accomplished using a method approved by the Manager, New York ACO,
ANE-170, Engine and Propeller Directorate, FAA; or TCCA; or
Bombardier, Inc.'s TCCA DAO. If approved by the DAO, the approval
must include the DAO-authorized signature.
Exact source excerpt. Text positions 17970–19267, end exclusive, in the original decoded publication. SHA-256: f744b8d5739ad8699399d9ab430df152bca498e48e897b0ed451f58059c49cde
Related Information
(k) Related Information
(1) Refer to Mandatory Continuing Airworthiness Information
(MCAI) Canadian Airworthiness Directive CF-2012-25, dated August 28,
2012, for related information. This MCAI may be found in the AD
docket on the Internet at http://www.regulations.gov by searching
for and locating Docket No. FAA-2013-0298.
(2) For service information identified in this AD that is not
incorporated by reference, contact Bombardier, Inc., Q-Series
Technical Help Desk, 123 Garratt Boulevard, Toronto, Ontario M3K
1Y5, Canada; telephone 416-375-4000; fax 416-375-4539; email
[email protected]; Internet http://www.bombardier.com.
You may view this referenced service information at the FAA,
Transport Airplane Directorate, 1601 Lind Avenue SW., Renton, WA.
For information on the availability of this material at the FAA,
call 425 227-1221.
Exact source excerpt. Text positions 19267–20131, end exclusive, in the original decoded publication. SHA-256: 2c2a20c64c225cb1b60532c87105c417c5a0c8a4d74785807f32cb69248f4ae9
Material Incorporated by Reference
(l) Material Incorporated by Reference
None
Exact source excerpt. Text positions 20131–20181, end exclusive, in the original decoded publication. SHA-256: 61afcc9595dc8a95a7eee15ef5d1465a9fe538e123bcecabc01a9e2b1e033c29
No replacement link has been established from this edition. The complete historical rule chain and current legal effect remain unknown.
Find all recorded historical references to AD 2013-15-06 · 0 printed reference observations in this pinned collection.
These are observations from one dated publication. Current legal status is unknown; aircraft applicability, installed configuration, compliance and burden require separate evidence. Missing or unparsed conditions remain unknown.
Why these observations are shown
They were extracted offline from the same immutable official HTML source as the complete recorded text. The dated source wording, original text coordinates and exact quote digests are retained. PDF/text agreement and current regulatory effect have not been qualified.
Observation revision: whole-ad-publication-clause-observations-1.0.1. Text SHA-256: 124ae3e06e629ce0cf3079f7426c10f5a0d80c6894596365f1ce4054c02b4a10. Source manifest: 36422b599ac45ad25b6fdc0e5ba284ebd7ce28e8d78731d9543892d1ed58d595.
Official source · 2014-09-15
Publication text
This is the complete recorded text of this dated publication.
Current legal effect is unknown. Aircraft applicability, installed configuration and compliance require separate evidence. PDF/text agreement has not been evaluated.
Read the complete official publication text
[Federal Register Volume 79, Number 178 (Monday, September 15, 2014)]
[Rules and Regulations]
[Pages 54891-54893]
From the Federal Register Online via the Government Publishing Office [www.gpo.gov]
[FR Doc No: 2014-21770]
[[Page 54891]]
-----------------------------------------------------------------------
DEPARTMENT OF TRANSPORTATION
Federal Aviation Administration
14 CFR Part 39
[Docket No. FAA-2013-0298; Directorate Identifier 2012-NM-175-AD;
Amendment 39-17522; AD 2013-15-06]
RIN 2120-AA64
Airworthiness Directives; Bombardier, Inc. Airplanes
AGENCY: Federal Aviation Administration (FAA), Department of
Transportation (DOT).
ACTION: Final rule.
-----------------------------------------------------------------------
SUMMARY: We are adopting a new airworthiness directive (AD) for certain
Bombardier, Inc. Model DHC-8-102, -103, -106, -201, -202, -301, -311,
and --315 airplanes. This AD was prompted by reports of dual
alternating current (AC) generator failure during flight. The failure
was attributed to wire chafing along the wing lower flap shroud. This
AD requires revising the maintenance program to incorporate certain
tasks for the electrical wiring interconnection system inspection
program. We are issuing this AD to prevent failure of both AC
generators due to wire chafing, which could result in loss of power to
the anti-icing heaters for the elevator horn, engine inlet, and
propeller, and consequent ice accumulation in these areas, which could
adversely affect the controllability of the airplane.
DATES: This AD becomes effective October 20, 2014.
ADDRESSES: You may examine the AD docket on the Internet at http://www.regulations.gov/#!docketDetail;D=FAA-2013-0298; or in person at the
Docket Management Facility, U.S. Department of Transportation, Docket
Operations, M-30, West Building Ground Floor, Room W12-140, 1200 New
Jersey Avenue SE., Washington, DC.
For service information referenced in this AD, contact Bombardier,
Inc., Q Series Technical Help Desk, 123 Garratt Boulevard, Toronto,
Ontario M3K 1Y5, Canada; telephone 416-375-4000; fax 416-375-4539;
email [email protected]; Internet http://www.bombardier.com. You may view this referenced service information at
the FAA, Transport Airplane Directorate, 1601 Lind Avenue SW., Renton,
WA. For information on the availability of this material at the FAA,
call 425-227-1221.
FOR FURTHER INFORMATION CONTACT: Assata Dessaline, Aerospace Engineer,
Avionics and Services Branch, ANE-172, FAA, New York Aircraft
Certification Office (ACO), 1600 Stewart Avenue, Suite 410, Westbury,
NY 11590; telephone 516-228-7301; fax 516-794-5531.
SUPPLEMENTARY INFORMATION:
Discussion
We issued a notice of proposed rulemaking (NPRM) to amend 14 CFR
part 39 by adding an AD that would apply to certain Bombardier, Inc.
Model DHC-8-102, -103, -106, -201, -202, -301, -311, and -315
airplanes. The NPRM published in the Federal Register on April 11, 2013
(78 FR 21573). The NPRM was prompted by reports of dual alternating
current (AC) generator failure during flight. The NPRM proposed to
require revising the maintenance program to incorporate certain tasks
for the electrical wiring interconnection system inspection program. We
are issuing this AD to prevent failure of both AC generators due to
wire chafing, which could result in loss of power to the anti-icing
heaters for the elevator horn, engine inlet, and propeller, and
consequent ice accumulation in these areas, which could adversely
affect the controllability of the airplane.
Transport Canada Civil Aviation (TCCA), which is the aviation
authority for Canada, has issued Canadian Airworthiness Directive CF-
2012-25, dated August 28, 2012 (referred to after this as the Mandatory
Continuing Airworthiness Information, or ``the MCAI''), to correct an
unsafe condition for certain Bombardier, Inc. Model DHC-8-102, -103, -
106, -201, -202, -301, -311, and -315 airplanes. The MCAI states:
There have been several reported occurrences of dual
[alternating current] AC Generator failure during flight, resulting
in the loss of the variable frequency AC System.
Investigations revealed wire chafing along the wing lower flap
shroud due to sagging wiring harnesses resting on the support
structure, missing teflon tape at the fairlead locations, and
missing grommets. Chafed wires may lead to arcing, local
overheating, and AC generator failure. The AC generators provide
power to the anti-icing heaters, including elevator horn heater,
engine inlet heater and propeller heater. Failure of both AC
generators would result in the loss of these systems and poses a
safety concern.
This [Canadian] AD mandates the inspection and rectification of
the wiring harness installations along the centre wing lower flap
shroud.
Required actions include revising the maintenance program by
incorporating electrical wiring interconnection system inspection
program tasks.
You may examine the MCAI in the AD docket on the Internet at http://www.regulations.gov/#!documentDetail;D=FAA-2013-0298-0002.
Comments
We gave the public the opportunity to participate in developing
this AD. We considered the comment received. The Air Line Pilots
Association, International stated that it supports the NPRM (78 FR
21573, April 11, 2013).
``Contacting the Manufacturer'' Paragraph in This AD
Since late 2006, we have included a standard paragraph titled
``Airworthy Product'' in all MCAI ADs in which the FAA develops an AD
based on a foreign authority's AD.
We have become aware that some operators have misunderstood or
misinterpreted the Airworthy Product paragraph to allow the owner/
operator to use messages provided by the manufacturer as approval of
deviations during the accomplishment of an AD-mandated action. The
Airworthy Product paragraph does not approve messages or other
information provided by the manufacturer for deviations to the
requirements of the AD-mandated actions. The Airworthy Product
paragraph only addresses the requirement to contact the manufacturer
for corrective actions for the identified unsafe condition and does not
cover deviations from other AD requirements. However, deviations to AD-
required actions are addressed in 14 CFR 39.17, and anyone may request
the approval for an alternative method of compliance to the AD-required
actions using the procedures found in 14 CFR 39.19.
To address this misunderstanding and misinterpretation of the
Airworthy Product paragraph, we have changed the paragraph and retitled
it ``Contacting the Manufacturer.'' This paragraph now clarifies that
for any requirement in this AD to obtain corrective actions from a
manufacturer, the actions must be accomplished using a method approved
by the FAA, Transport Canada Civil Aviation (TCCA), or Bombardier,
Inc.'s TCCA Design Organization Approval (DOA).
The Contacting the Manufacturer paragraph also clarifies that, if
approved by the DAO, the approval must include the DAO-authorized
signature. The DAO signature indicates that the data and information
contained in the document are TCCA-approved, which is also FAA-
approved. Messages and other information provided by the manufacturer
that do not contain the DAO-authorized signature approval are not TCCA-
approved, unless TCCA
[[Page 54892]]
directly approves the manufacturer's message or other information.
This clarification does not remove flexibility previously afforded
by the Airworthy Product paragraph. Consistent with long-standing FAA
policy, such flexibility was never intended for required actions. This
is also consistent with the recommendation of the Airworthiness
Directive Implementation Aviation Rulemaking Committee to increase
flexibility in complying with ADs by identifying those actions in
manufacturers' service instructions that are ``Required for
Compliance'' with ADs. We continue to work with manufacturers to
implement this recommendation. But once we determine that an action is
required, any deviation from the requirement must be approved as an
alternative method of compliance.
We also have decided not to include a generic reference to either
the ``delegated agent'' or ``design approval holder (DAH) with State of
Design Authority design organization approval,'' but instead we have
provided the specific delegation approval granted by the State of
Design Authority for the DAH.
Explanation of Changes to This AD
Paragraph (g) of this AD was revised to state that incorporation of
tasks into the maintenance or inspection program, as applicable, must
be done in accordance with a method approved by the Manager, New York
Aircraft Certification Office (ACO), ANE-170, FAA; or Transport Canada
Civil Aviation (TCCA); or Bombardier, Inc.'s TCCA DAO. The service
information previously referenced in paragraph (g) of the NPRM (78 FR
21573, April 11, 2013) is now referenced as guidance material in Notes
1, 2, and 3 to paragraph (g) of this AD.
Conclusion
We reviewed the relevant data, considered the comment received, and
determined that air safety and the public interest require adopting
this AD with the changes described previously and minor editorial
changes. We have determined that these minor changes:
<bullet> Are consistent with the intent that was proposed in the
NPRM (78 FR 21573, April 11, 2013) for correcting the unsafe condition;
and
<bullet> Do not add any additional burden upon the public than was
already proposed in the NPRM (78 FR 21573, April 11, 2013).
We also determined that these changes will not increase the
economic burden on any operator or increase the scope of this AD.
Costs of Compliance
We estimate that this AD affects 89 airplanes of U.S. registry.
We also estimate that it will take about 1 work-hour per product to
comply with the basic requirements of this AD. The average labor rate
is $85 per work-hour. Based on these figures, we estimate the cost of
this AD to the U.S. operators to be $7,565, or $85 per product.
Authority for This Rulemaking
Title 49 of the United States Code specifies the FAA's authority to
issue rules on aviation safety. Subtitle I, section 106, describes the
authority of the FAA Administrator. ``Subtitle VII: Aviation
Programs,'' describes in more detail the scope of the Agency's
authority.
We are issuing this rulemaking under the authority described in
``Subtitle VII, Part A, Subpart III, Section 44701: General
requirements.'' Under that section, Congress charges the FAA with
promoting safe flight of civil aircraft in air commerce by prescribing
regulations for practices, methods, and procedures the Administrator
finds necessary for safety in air commerce. This regulation is within
the scope of that authority because it addresses an unsafe condition
that is likely to exist or develop on products identified in this
rulemaking action.
Regulatory Findings
We determined that this AD will not have federalism implications
under Executive Order 13132. This AD will not have a substantial direct
effect on the States, on the relationship between the national
government and the States, or on the distribution of power and
responsibilities among the various levels of government.
For the reasons discussed above, I certify that this AD:
1. Is not a ``significant regulatory action'' under Executive Order
12866;
2. Is not a ``significant rule'' under the DOT Regulatory Policies
and Procedures (44 FR 11034, February 26, 1979);
3. Will not affect intrastate aviation in Alaska; and
4. Will not have a significant economic impact, positive or
negative, on a substantial number of small entities under the criteria
of the Regulatory Flexibility Act.
We prepared a regulatory evaluation of the estimated costs to
comply with this AD and placed it in the AD docket.
Examining the AD Docket
You may examine the AD docket on the Internet at http://www.regulations.gov/#!docketDetail;D=FAA-2013-0298; or in person at the
Docket Operations office between 9 a.m. and 5 p.m., Monday through
Friday, except Federal holidays. The AD docket contains this AD, the
MCAI, the regulatory evaluation, any comments received, and other
information. The street address for the Docket Operations office
(telephone (800) 647-5527) is in the ADDRESSES section.
List of Subjects in 14 CFR Part 39
Air transportation, Aircraft, Aviation safety, Incorporation by
reference, Safety.
Adoption of the Amendment
Accordingly, under the authority delegated to me by the
Administrator, the FAA amends 14 CFR part 39 as follows:
PART 39--AIRWORTHINESS DIRECTIVES
0
1. The authority citation for part 39 continues to read as follows:
Authority: 49 U.S.C. 106(g), 40113, 44701.
Sec. 39.13 [Amended]
0
2. The FAA amends Sec. 39.13 by adding the following new AD:
2013-15-06 Bombardier, Inc.: Amendment 39-17522. Docket No. FAA-
2013-0298; Directorate Identifier 2012-NM-175-AD.
(a) Effective Date
This airworthiness directive (AD) becomes effective October 20,
2014.
(b) Affected ADs
None.
(c) Applicability
This AD applies to Bombardier, Inc. Model DHC-8-102, -103, -106,
-201, -202, -301, -311, and -315 airplanes, certificated in any
category, serial numbers 003 and subsequent.
(d) Subject
Air Transport Association (ATA) of America Code 24, Electrical
Power.
(e) Reason
This AD was prompted by reports of dual alternating current (AC)
generator failure during flight. The failure was attributed to wire
chafing along the wing lower flap shroud. We are issuing this AD to
prevent failure of both AC generators due to wire chafing, which
could result in loss of power to the anti-icing heaters for the
elevator horn, engine inlet, and propeller, and consequent ice
accumulation in these areas, which could adversely affect the
controllability of the airplane.
[[Page 54893]]
(f) Compliance
Comply with this AD within the compliance times specified,
unless already done.
(g) Revision of Maintenance or Inspection Program
Within 30 days after the effective date of this AD: Incorporate
tasks for performing a general visual inspection of the wiring and
associated electrical wiring interconnection system (EWIS)
components into the airplane maintenance or inspection program, as
applicable, in accordance with a method approved by the Manager, New
York Aircraft Certification Office (ACO), ANE-170, FAA.
Note 1 to paragraph (g) of this AD: For Model DHC-8-100 series
airplanes, the instructions provided in de Havilland Dash 8
Maintenance Task Cards 531X1 and 631X1, ``General visual inspection
of the wiring and associated electrical wiring interconnection
system (EWIS) components,'' in Section 8, ``Electrical Wiring
Interconnection System Inspection Program,'' of the Bombardier (de
Havilland) Dash 8 Series 100 Maintenance Review Board Report of the
Bombardier (de Havilland) Dash 8 Series 100 Maintenance Program
Manual PSM 1-8-7, Revision 25, dated February 20, 2012, provides
guidance for revising the maintenance program to include general
visual inspections of the wiring and associated EWIS components.
This service information is not incorporated by reference in this
AD.
Note 2 to paragraph (g) of this AD: For Model DHC-8-200 series
airplanes, the instructions provided in de Havilland Dash 8
Maintenance Task Cards 531X1 and 631X1, ``General visual inspection
of the wiring and associated electrical wiring interconnection
system (EWIS) components,'' in Section 8, ``Electrical Wiring
Interconnection System Inspection Program,'' of the Bombardier (de
Havilland) Dash 8 Series 200 Maintenance Review Board Report of the
Bombardier (de Havilland) Dash 8 Series 200 Maintenance Program
Manual PSM 1-82-7, Revision 16, dated February 20, 2012, provides
guidance for revising the maintenance program to include general
visual inspections of the wiring and associated EWIS components.
This service information is not incorporated by reference in this
AD.
Note 3 to paragraph (g) of this AD: For Model DHC-8-300 series
airplanes, the instructions provided in de Havilland Dash 8
Maintenance Task Cards 531X1 and 631X1, ``General visual inspection
of the wiring and associated electrical wiring interconnection
system (EWIS) components,'' in Section 8, ``Electrical Wiring
Interconnection System Inspection Program,'' of the Bombardier (de
Havilland) Dash 8 Series 300 Maintenance Review Board Report of the
Bombardier (de Havilland) Dash 8 Series 300 Bombardier Maintenance
Program Manual PSM 1-83-7, Revision 25, dated February 20, 2012,
provides guidance for revising the maintenance program to include
general visual inspections of the wiring and associated EWIS
components. This service information is not incorporated by
reference in this AD.
(h) Initial Task Compliance Time
The initial compliance time for the tasks incorporated into the
maintenance or inspection program, as applicable, specified in
paragraph (g) of this AD, is at the applicable time specified in
paragraph (h)(1) or (h)(2) of this AD.
(1) For airplanes with 45,000 total flight hours or more as of
the effective date of this AD: Within 1,000 flight hours after the
effective date of this AD.
(2) For airplanes with less than 45,000 total flight hours as of
the effective date of this AD: Within 6,000 flight hours after the
effective date of this AD, but not to exceed 46,000 total flight
hours.
(i) No Alternative Actions or Intervals
After accomplishing the revisions required by paragraph (g) of
this AD, no alternative actions (e.g., inspections) or intervals may
be used, unless the actions and intervals are approved as an
alternative method of compliance (AMOC) in accordance with the
procedures specified in paragraph (j)(1) of this AD.
(j) Other FAA AD Provisions
The following provisions also apply to this AD:
(1) Alternative Methods of Compliance (AMOCs): The Manager, New
York ACO, ANE-170, FAA, has the authority to approve AMOCs for this
AD, if requested using the procedures found in 14 CFR 39.19. In
accordance with 14 CFR 39.19, send your request to your principal
inspector or local Flight Standards District Office, as appropriate.
If sending information directly to the ACO, send it to ATTN: Program
Manager, Continuing Operational Safety, FAA, New York ACO, 1600
Stewart Avenue, Suite 410, Westbury, NY 11590; telephone 516-228-
7300; fax 516-794-5531. Before using any approved AMOC, notify your
appropriate principal inspector, or lacking a principal inspector,
the manager of the local flight standards district office/
certificate holding district office. The AMOC approval letter must
specifically reference this AD.
(2) Contacting the Manufacturer: For any requirement in this AD
to obtain corrective actions from a manufacturer, the action must be
accomplished using a method approved by the Manager, New York ACO,
ANE-170, Engine and Propeller Directorate, FAA; or TCCA; or
Bombardier, Inc.'s TCCA DAO. If approved by the DAO, the approval
must include the DAO-authorized signature.
(k) Related Information
(1) Refer to Mandatory Continuing Airworthiness Information
(MCAI) Canadian Airworthiness Directive CF-2012-25, dated August 28,
2012, for related information. This MCAI may be found in the AD
docket on the Internet at http://www.regulations.gov by searching
for and locating Docket No. FAA-2013-0298.
(2) For service information identified in this AD that is not
incorporated by reference, contact Bombardier, Inc., Q-Series
Technical Help Desk, 123 Garratt Boulevard, Toronto, Ontario M3K
1Y5, Canada; telephone 416-375-4000; fax 416-375-4539; email
[email protected]; Internet http://www.bombardier.com.
You may view this referenced service information at the FAA,
Transport Airplane Directorate, 1601 Lind Avenue SW., Renton, WA.
For information on the availability of this material at the FAA,
call 425 227-1221.
(l) Material Incorporated by Reference
None
Issued in Renton, Washington, on July 12, 2013.
Jeffrey E. Duven,
Manager, Transport Airplane Directorate, Aircraft Certification
Service.
[FR Doc. 2014-21770 Filed 9-12-14; 8:45 am]
BILLING CODE 4910-13-P
Why this text is shown
The complete text was extracted from the official GovInfo HTML edition for this publication. Acquired 2026-10-09T02:37:31.730353+00:00. Text extraction preserves the recorded source wording; it does not determine current requirements.
Open the captured official edition
- Source SHA-256
- 592a0e24f556f5af790cdbc018063c18c07d26ccb24e91248bdb227daa088d94
- Text SHA-256
- 124ae3e06e629ce0cf3079f7426c10f5a0d80c6894596365f1ce4054c02b4a10
Return to the full metadata catalog · Search complete publication text · Explore retained publication text and evidence
Coverage and limits
These are dated publication metadata, recorded clauses and literal source observations. Word, model-label, header and reference matches do not establish current legal effect, manufacturer/model identity, aircraft applicability, installed configuration or compliance.
The collection uses 33 explicit annual source snapshots. Source captures and operative-text qualifications have separate states. Missing information remains unknown.