Published 2018-02-23 · Federal Register document 2018-03438
Airworthiness Directives; Bombardier, Inc., Airplanes
Publication summary
We are adopting a new airworthiness directive (AD) for certain Bombardier, Inc., Model CL-600-2C10 (Regional Jet Series 700, 701, & 702), CL-600-2D15 (Regional Jet Series 705), CL-600-2D24 (Regional Jet Series 900), and CL-600-2E25 (Regional Jet Series 1000) airplanes. This AD was prompted by several incidents of electrical shorting and sparks caused by de-icing fluid leaks between flight deck windshields and side windows. This AD requires water spray tests and general visual inspections for water in the flight deck compartment, and water removal and sealant application if necessary. We are issuing this AD to address the unsafe condition on these products.
Why this record is shown
Source: Federal Register annual FAA metadata. Acquired 2026-09-03T22:23:58.123663+00:00. The title, summary and date are source facts.
- Source revision
- federal_register_ad_metadata_2018-258c65fa72d503e0
- Source row
- results[60]
- Raw source SHA-256
- 258c65fa72d503e0b0dfb928a28beb1793ddc7dd9218bce0413e53dfe11d78fb
Final-rule publication
Recorded publication clauses
- AD identifier printed in this edition
- 2018-04-04
- Effective date printed in this edition
- 2018-03-30
Read 13 complete recorded clauses
Effective Date
(a) Effective Date
This AD is effective March 30, 2018.
Exact source excerpt. Text positions 11027–11089, end exclusive, in the original decoded publication. SHA-256: 7fc3044d85f159cc1a41df7b96c728edbe43fcf2bed264a0432c4f153a5f1a7a
Affected ADs
(b) Affected ADs
None.
Exact source excerpt. Text positions 11089–11118, end exclusive, in the original decoded publication. SHA-256: 871a4afc60ceeae06e8010585055188633d616078500c45937092bfe892239c0
Applicability wording · Applicability
(c) Applicability
This AD applies to the airplanes identified in paragraphs
(c)(1), (c)(2), and (c)(3) of this AD, certificated in any category.
(1) Bombardier, Inc., Model CL-600-2C10 (Regional Jet Series
700, 701, & 702) airplanes, serial numbers 10003 through 10342
inclusive.
(2) Bombardier, Inc., Model CL-600-2D15 (Regional Jet Series
705) and Model CL-600-2D24 (Regional Jet Series 900) airplanes,
serial numbers 15001 through 15367 inclusive.
(3) Bombardier, Inc., Model CL-600-2E25 (Regional Jet Series
1000) airplanes, serial numbers 19001 through 19041 inclusive.
Exact source excerpt. Text positions 11118–11717, end exclusive, in the original decoded publication. SHA-256: 23217a41d5828b634efddfe2627afd248a4e557954aafe2baae47727aab2d220
Subject
(d) Subject
Air Transport Association (ATA) of America Code 56, Windows.
[[Page 7974]]
Exact source excerpt. Text positions 11717–11811, end exclusive, in the original decoded publication. SHA-256: f9f5e8d727102b321fa5b4ee2d13c3e558f181fcc607dd3ba05fdf687eca46a9
Reason
(e) Reason
This AD was prompted by several incidents of electrical shorting
and sparks caused by de-icing fluid leaks between flight deck
windshields and side windows. We are issuing this AD to detect and
correct de-icing fluid entering the flight deck, which could damage
the flight deck floodlight wires and electrical connections, and
ultimately could lead to a fire in the flight deck compartment.
Exact source excerpt. Text positions 11811–12224, end exclusive, in the original decoded publication. SHA-256: 0ace5d231b0677732577d4a247441e225a3127774edce38902dbd3cd071ae6eb
Compliance
(f) Compliance
Comply with this AD within the compliance times specified,
unless already done.
Exact source excerpt. Text positions 12224–12326, end exclusive, in the original decoded publication. SHA-256: 00fbfa31932483f627d0ce0a11cbd2e35e15d9231842b91ac85623ce533912d3
Left Flight Deck Windshield and Side Window Spray Test, Inspection, Water Removal and Sealant Application
(g) Left Flight Deck Windshield and Side Window Spray Test, Inspection,
Water Removal and Sealant Application
For airplanes on which a left flight deck windshield or a left
flight deck side window was replaced as specified in Bombardier
Aircraft Maintenance Manual (AMM) task 56-11-01-400-801, Revision
48, dated March 25, 2015, or any previous revision of that task; or
Bombardier AMM task 56-12-01-400-801, Revision 48, dated March 25,
2015, or any previous revision of that task: At the applicable time
specified in paragraph (g)(1) or (g)(2) of this AD, perform a water
spray test and do a general visual inspection of the left flight
deck windshield and left flight deck side window for evidence of
water ingress into the flight deck, in accordance with Part A of the
Accomplishment Instructions of Bombardier Service Bulletin 670BA-56-
003, Revision A, dated April 13, 2016. If water is found in the
flight deck compartment: Before further flight, remove the water,
and apply sealant on the left flight deck windows in accordance with
Part C of the Accomplishment Instructions of Bombardier Service
Bulletin 670BA-56-003, Revision A, dated April 13, 2016.
(1) For airplanes on which Bombardier in-service ModSum
IS67033110181 has not been incorporated: Within 2,500 flight hours
after the effective date of this AD.
(2) For airplanes on which Bombardier in-service ModSum
IS67033110181 has been incorporated: Within 6,600 flight hours after
the effective date of this AD.
Exact source excerpt. Text positions 12326–13837, end exclusive, in the original decoded publication. SHA-256: 0670864116f71c17caa6c4514c1e7286508f7f6ecf50108ab7b18c0ed57d6373
Right Flight Deck Windshield and Side Window Spray Test, Inspection, Water Removal and Sealant Application
(h) Right Flight Deck Windshield and Side Window Spray Test,
Inspection, Water Removal and Sealant Application
For airplanes on which a right flight deck windshield or a right
flight deck side window was replaced as specified in Bombardier AMM
task 56-11-01-400-801, Revision 48, dated March 25, 2015, or any
previous revision of that task; or Bombardier AMM task 56-12-01-400-
801, Revision 48, dated March 25, 2015, or any previous revision of
that task: At the applicable time specified in paragraph (h)(1) or
(h)(2) of this AD, perform a water spray test and do a general
visual inspection of the right flight deck windshield and right
flight deck side window for evidence of water ingress into the
flight deck, in accordance with Part B of the Accomplishment
Instructions of Bombardier Service Bulletin 670BA-56-003, Revision
A, dated April 13, 2016. If water is found in the flight deck
compartment: Before further flight, remove the water, and apply
sealant on the right flight deck windows in accordance with Part D
of the Accomplishment Instructions of Bombardier Service Bulletin
670BA-56-003, Revision A, dated April 13, 2016.
(1) For airplanes on which Bombardier in-service ModSum
IS67033110181 has not been incorporated: Within 2,500 flight hours
after the effective date of this AD.
(2) For airplanes on which Bombardier in-service ModSum
IS67033110181 has been incorporated: Within 6,600 flight hours after
the effective date of this AD.
Exact source excerpt. Text positions 13837–15324, end exclusive, in the original decoded publication. SHA-256: 308da8fdd5a0cf96f0149ad9cfc0255b5b6ca62c55cad5473d88992fb3c806e3
Credit for Previous Actions
(i) Credit for Previous Actions
(1) This paragraph provides credit for actions required by
paragraph (g) of this AD, if those actions were performed before the
effective date of this AD using the service information specified in
paragraphs (i)(1)(i), (i)(1)(ii), or (i)(1)(iii) of this AD;
provided that the left flight deck side window or left flight deck
windshield have not been subsequently replaced as specified in
Bombardier AMM task 56-11-01-400-801, Revision 48, dated March 25,
2015, or any previous revision of that task; or Bombardier AMM task
56-12-01-400-801, Revision 48, dated March 25, 2015, or any previous
revision of that task.
(i) Bombardier Alert Service Bulletin A670BA-56-002, dated
January 7, 2008.
(ii) Bombardier Alert Service Bulletin A670BA-56-002, Revision
A, dated February 26, 2008.
(iii) Part A and Part C, as applicable, of the Accomplishment
Instructions of Bombardier Service Bulletin 670BA-56-003, dated May
28, 2015.
(2) This paragraph provides credit for actions required by
paragraph (h) of this AD, if those actions were performed before the
effective date of this AD using the service information specified in
paragraphs (i)(2)(i), (i)(2)(ii), or (i)(2)(iii) of this AD;
provided that the right flight deck side window or right flight deck
windshield have not been subsequently replaced as specified in
Bombardier AMM task 56-11-01-400-801, Revision 48, dated March 25,
2015, or any previous revision of that task; or Bombardier AMM task
56-12-01-400-801, Revision 48, dated March 25, 2015, or any previous
revision of that task.
(i) Bombardier Alert Service Bulletin A670BA-56-002, dated
January 7, 2008.
(ii) Bombardier Alert Service Bulletin A670BA-56-002, Revision
A, dated February 26, 2008.
(iii) Part B and Part D, as applicable, of the Accomplishment
Instructions of Bombardier Service Bulletin 670BA-56-003, dated May
28, 2015.
Exact source excerpt. Text positions 15324–17262, end exclusive, in the original decoded publication. SHA-256: e7c3285c61f5cce726ad83d65c4931667e1040febc787f8594435ad3e67dff8e
Parts Installation Limitations
(j) Parts Installation Limitations
(1) As of the effective date of this AD, no person may install
on any airplane a left or right flight deck windshield as specified
in Bombardier AMM task 56-11-01-400-801, Revision 48, dated March
25, 2015, or any previous revision of that task.
(2) As of the effective date of this AD, no person may install
on any airplane a left or right flight deck side window as specified
in Bombardier AMM task 56-12-01-400-801, Revision 48, dated March
25, 2015, or any previous revision of that task.
Exact source excerpt. Text positions 17262–17806, end exclusive, in the original decoded publication. SHA-256: 461fad993137d7fffd51a21c5d014187e121c105b1aee894b5b89449a81a370e
Other FAA AD Provisions
(k) Other FAA AD Provisions
The following provisions also apply to this AD:
(1) Alternative Methods of Compliance (AMOCs): The Manager, New
York ACO Branch, FAA, has the authority to approve AMOCs for this
AD, if requested using the procedures found in 14 CFR 39.19. In
accordance with 14 CFR 39.19, send your request to your principal
inspector or local Flight Standards District Office, as appropriate.
If sending information directly to the manager of the certification
office, send it to ATTN: Program Manager, Continuing Operational
Safety, FAA, New York ACO Branch, 1600 Stewart Avenue, Suite 410,
Westbury, NY 11590; telephone 516-228-7300; fax 516-794-5531. Before
using any approved AMOC, notify your appropriate principal
inspector, or lacking a principal inspector, the manager of the
local flight standards district office/certificate holding district
office.
(2) Contacting the Manufacturer: For any requirement in this AD
to obtain corrective actions from a manufacturer, the action must be
accomplished using a method approved by the Manager, New York ACO
Branch, FAA; or Transport Canada Civil Aviation (TCCA); or
Bombardier, Inc.'s TCCA Design Approval Organization (DAO). If
approved by the DAO, the approval must include the DAO-authorized
signature.
Exact source excerpt. Text positions 17806–19108, end exclusive, in the original decoded publication. SHA-256: 52299b0e9c1d4bcd236f8e606a01addf16caebb358abe676926bf4815c4c1cb6
Related Information
(l) Related Information
(1) Refer to Mandatory Continuing Airworthiness Information
(MCAI) Canadian Airworthiness Directive CF-2017-28, dated August 23,
2017, for related information. This MCAI may be found in the AD
docket on the internet at http://www.regulations.gov by searching
for and locating Docket No. FAA-2017-1025.
(2) For more information about this AD, contact Steven
Dzierzynski, Aerospace Engineer, Avionics and Administrative
Services Section, FAA, New York ACO Branch, 1600 Stewart Avenue,
Suite 410, Westbury, NY 11590; telephone 516-228-7367; fax 516-794-
5531.
(3) Service information identified in this AD that is not
incorporated by reference is available at the addresses specified in
paragraphs (m)(3) and (m)(4) of this AD.
Exact source excerpt. Text positions 19108–19881, end exclusive, in the original decoded publication. SHA-256: b24b015ec6624d930928bec76f8df0d5000b94ee3b018e366d693e29c149ec87
Material Incorporated by Reference
(m) Material Incorporated by Reference
(1) The Director of the Federal Register approved the
incorporation by reference (IBR) of the service information listed
in this paragraph under 5 U.S.C. 552(a) and 1 CFR part 51.
(2) You must use this service information as applicable to do
the actions required by this AD, unless this AD specifies otherwise.
(i) Bombardier Service Bulletin 670BA-56-003, Revision A, dated
April 13, 2016.
(ii) Reserved.
(3) For service information identified in this AD, contact
Bombardier, Inc., 400 C[ocirc]te-Vertu Road West, Dorval,
Qu[eacute]bec H4S 1Y9, Canada; Widebody Customer Response Center
North America toll-free telephone 1-866-538-1247 or direct-dial
telephone 1-514-855-2999; fax 514-855-7401; email
[email protected]; internet http://www.bombardier.com.
[[Page 7975]]
(4) You may view this service information at the FAA, Transport
Standards Branch, 1601 Lind Avenue SW, Renton, WA. For information
on the availability of this material at the FAA, call 425-227-1221.
(5) You may view this service information that is incorporated
by reference at the National Archives and Records Administration
(NARA). For information on the availability of this material at
NARA, call 202-741-6030, or go to: http://www.archives.gov/federal-register/cfr/ibr-locations.html.
Exact source excerpt. Text positions 19881–21229, end exclusive, in the original decoded publication. SHA-256: 8daaaad010cba114a580511de78a25db12b82a861b65e9136bdb8ccd1120bddf
No replacement link has been established from this edition. The complete historical rule chain and current legal effect remain unknown.
Find all recorded historical references to AD 2018-04-04 · 0 printed reference observations in this pinned collection.
These are observations from one dated publication. Current legal status is unknown; aircraft applicability, installed configuration, compliance and burden require separate evidence. Missing or unparsed conditions remain unknown.
Why these observations are shown
They were extracted offline from the same immutable official HTML source as the complete recorded text. The dated source wording, original text coordinates and exact quote digests are retained. PDF/text agreement and current regulatory effect have not been qualified.
Observation revision: whole-ad-publication-clause-observations-1.0.1. Text SHA-256: db586b5ef685ed673683aec99e8ba6f9da976875963943d1ffa23f42d715aa3c. Source manifest: 65e868ddacf738d8471e3112dbaf7d01f0a33a1f6aa927442440a15d6641c33d.
Official source · 2018-02-23
Publication text
This is the complete recorded text of this dated publication.
Current legal effect is unknown. Aircraft applicability, installed configuration and compliance require separate evidence. PDF/text agreement has not been evaluated.
Read the complete official publication text
[Federal Register Volume 83, Number 37 (Friday, February 23, 2018)]
[Rules and Regulations]
[Pages 7972-7975]
From the Federal Register Online via the Government Publishing Office [www.gpo.gov]
[FR Doc No: 2018-03438]
-----------------------------------------------------------------------
DEPARTMENT OF TRANSPORTATION
Federal Aviation Administration
14 CFR Part 39
[Docket No. FAA-2017-1025; Product Identifier 2017-NM-137-AD; Amendment
39-19199; AD 2018-04-04]
RIN 2120-AA64
Airworthiness Directives; Bombardier, Inc., Airplanes
AGENCY: Federal Aviation Administration (FAA), Department of
Transportation (DOT).
ACTION: Final rule.
-----------------------------------------------------------------------
SUMMARY: We are adopting a new airworthiness directive (AD) for certain
Bombardier, Inc., Model CL-600-2C10 (Regional Jet Series 700, 701, &
702), CL-600-2D15 (Regional Jet Series 705), CL-600-2D24 (Regional Jet
Series 900), and CL-600-2E25 (Regional Jet Series 1000) airplanes. This
AD was prompted by several incidents of electrical shorting and sparks
caused by de-icing fluid leaks between flight deck windshields and side
windows. This AD requires water spray tests and general visual
inspections for water in the flight deck compartment, and water removal
and sealant application if necessary. We are issuing this AD to address
the unsafe condition on these products.
DATES: This AD is effective March 30, 2018.
The Director of the Federal Register approved the incorporation by
reference of a certain publication listed in this AD as of March 30,
2018.
ADDRESSES: For service information identified in this final rule,
contact Bombardier, Inc., 400 C[ocirc]te Vertu Road West, Dorval,
Qu[eacute]bec H4S 1Y9, Canada; Widebody Customer Response Center North
America toll-free telephone 1-866-538-1247 or direct-dial telephone 1-
514-855-2999; fax 514-855-7401; email [email protected];
internet http://www.bombardier.com. You may view this service
information at the FAA, Transport Standards Branch, 1601 Lind Avenue
SW, Renton, WA. For information on the availability of this material at
the FAA, call 425-227-1221. It is also available on the internet at
http://www.regulations.gov by searching for and locating Docket No.
FAA-2017-1025.
Examining the AD Docket
You may examine the AD docket on the internet at http://www.regulations.gov by searching for and locating Docket No. FAA-2017-
1025; or in person at the Docket Management Facility between 9 a.m. and
5 p.m., Monday through Friday, except Federal holidays. The AD docket
contains this AD, the regulatory evaluation, any comments received, and
other information. The street address for the Docket Office (telephone
800-647-5527) is Docket Management Facility, U.S. Department of
Transportation, Docket Operations, M-30, West Building Ground Floor,
Room W12-140, 1200 New Jersey Avenue SE, Washington, DC 20590.
FOR FURTHER INFORMATION CONTACT: Steven Dzierzynski, Aerospace
Engineer, Avionics and Administrative Services Section, FAA, New York
ACO Branch, 1600 Stewart Avenue, Suite 410, Westbury, NY 11590;
telephone 516-228-7367; fax 516-794-5531.
SUPPLEMENTARY INFORMATION:
Discussion
We issued a notice of proposed rulemaking (NPRM) to amend 14 CFR
part 39 by adding an AD that would apply to certain Bombardier, Inc.,
Model CL-600-2C10 (Regional Jet Series 700, 701, & 702), CL-600-2D15
(Regional Jet Series 705), CL-600-2D24 (Regional Jet Series 900), and
CL-600-2E25 (Regional Jet Series 1000) airplanes. The NPRM published in
the Federal Register on November 17, 2017 (82 FR 54304) (``the NPRM'').
Transport Canada Civil Aviation (TCCA), which is the aviation
authority for Canada, has issued Canadian Airworthiness Directive CF-
2017-28, dated August 23, 2017 (referred to after this as the Mandatory
Continuing Airworthiness Information, or ``the MCAI''), to correct an
unsafe condition for certain Bombardier, Inc., Model CL-600-2C10
(Regional Jet Series 700, 701, & 702), CL-600-2D15 (Regional Jet Series
705), CL-600-2D24 (Regional Jet Series 900), and CL-600-2E25 (Regional
Jet Series 1000) airplanes. The MCAI states:
Several incidents of electrical shorting and sparks have been
reported in the cockpit of CL-600-2C10 and CL-600-2D24 aeroplanes.
De-icing fluid can leak between the windshields and side windows,
leading to possible damage to the cockpit floodlight wires and
electrical connections. If not corrected, this condition may result
in a flight compartment fire.
This [Canadian] AD is issued to mandate a water spray test and
[general visual] inspection for evidence of fluid ingress into the
flight compartment. It also provides mandatory instructions for
sealant application if required.
You may examine the MCAI in the AD docket on the internet at http://www.regulations.gov by searching for and locating Docket No. FAA-2017-
1025.
Comments
We gave the public the opportunity to participate in developing
this final rule. We received no comments on the NPRM or on the
determination of the cost to the public.
Conclusion
We reviewed the relevant data and determined that air safety and
the public interest require adopting this AD as proposed except for
minor editorial changes. We have determined that these minor changes:
<bullet> Are consistent with the intent that was proposed in the
NPRM for correcting the unsafe condition; and
[[Page 7973]]
<bullet> Do not add any additional burden upon the public than was
already proposed in the NPRM.
Related Service Information Under 1 CFR Part 51
Bombardier, Inc., has issued Service Bulletin 670BA-56-003,
Revision A, dated April 13, 2016. This service information describes
procedures for doing water spray tests on the flight deck windows,
doing general visual inspections for water in the flight deck
compartment, removing water, and applying sealant to the flight deck
windows. This service information is reasonably available because the
interested parties have access to it through their normal course of
business or by the means identified in the ADDRESSES section.
Costs of Compliance
We estimate that this AD affects 543 airplanes of U.S. registry.
We estimate the following costs to comply with this AD:
Estimated Costs
----------------------------------------------------------------------------------------------------------------
Cost per Cost on U.S.
Action Labor cost Parts cost product operators
----------------------------------------------------------------------------------------------------------------
Spray tests and inspections........... 2 work-hours x $85 per $0 $170 $92,310
hour = $170.
----------------------------------------------------------------------------------------------------------------
We estimate the following costs to do any necessary water removal
and sealant application that would be required based on the results of
the inspection. We have no way of determining the number of airplanes
that might need this water removal and sealant application:
On-Condition Costs
----------------------------------------------------------------------------------------------------------------
Cost per
Action Labor cost Parts cost product
----------------------------------------------------------------------------------------------------------------
Water removal and sealant application......... 4 work-hours x $85 per hour = $308 $648
$340.
----------------------------------------------------------------------------------------------------------------
Authority for This Rulemaking
Title 49 of the United States Code specifies the FAA's authority to
issue rules on aviation safety. Subtitle I, section 106, describes the
authority of the FAA Administrator. ``Subtitle VII: Aviation
Programs,'' describes in more detail the scope of the Agency's
authority.
We are issuing this rulemaking under the authority described in
``Subtitle VII, Part A, Subpart III, Section 44701: General
requirements.'' Under that section, Congress charges the FAA with
promoting safe flight of civil aircraft in air commerce by prescribing
regulations for practices, methods, and procedures the Administrator
finds necessary for safety in air commerce. This regulation is within
the scope of that authority because it addresses an unsafe condition
that is likely to exist or develop on products identified in this
rulemaking action.
This AD is issued in accordance with authority delegated by the
Executive Director, Aircraft Certification Service, as authorized by
FAA Order 8000.51C. In accordance with that order, issuance of ADs is
normally a function of the Compliance and Airworthiness Division, but
during this transition period, the Executive Director has delegated the
authority to issue ADs applicable to transport category airplanes to
the Director of the System Oversight Division.
Regulatory Findings
We determined that this AD will not have federalism implications
under Executive Order 13132. This AD will not have a substantial direct
effect on the States, on the relationship between the national
government and the States, or on the distribution of power and
responsibilities among the various levels of government.
For the reasons discussed above, I certify that this AD:
1. Is not a ``significant regulatory action'' under Executive Order
12866,
2. Is not a ``significant rule'' under the DOT Regulatory Policies
and Procedures (44 FR 11034, February 26, 1979),
3. Will not affect intrastate aviation in Alaska, and
4. Will not have a significant economic impact, positive or
negative, on a substantial number of small entities under the criteria
of the Regulatory Flexibility Act.
List of Subjects in 14 CFR Part 39
Air transportation, Aircraft, Aviation safety, Incorporation by
reference, Safety.
Adoption of the Amendment
Accordingly, under the authority delegated to me by the
Administrator, the FAA amends 14 CFR part 39 as follows:
PART 39--AIRWORTHINESS DIRECTIVES
0
1. The authority citation for part 39 continues to read as follows:
Authority: 49 U.S.C. 106(g), 40113, 44701.
Sec. 39.13 [Amended]
0
2. The FAA amends Sec. 39.13 by adding the following new airworthiness
directive (AD):
2018-04-04 Bombardier, Inc.: Amendment 39-19199; Docket No. FAA-
2017-1025; Product Identifier 2017-NM-137-AD.
(a) Effective Date
This AD is effective March 30, 2018.
(b) Affected ADs
None.
(c) Applicability
This AD applies to the airplanes identified in paragraphs
(c)(1), (c)(2), and (c)(3) of this AD, certificated in any category.
(1) Bombardier, Inc., Model CL-600-2C10 (Regional Jet Series
700, 701, & 702) airplanes, serial numbers 10003 through 10342
inclusive.
(2) Bombardier, Inc., Model CL-600-2D15 (Regional Jet Series
705) and Model CL-600-2D24 (Regional Jet Series 900) airplanes,
serial numbers 15001 through 15367 inclusive.
(3) Bombardier, Inc., Model CL-600-2E25 (Regional Jet Series
1000) airplanes, serial numbers 19001 through 19041 inclusive.
(d) Subject
Air Transport Association (ATA) of America Code 56, Windows.
[[Page 7974]]
(e) Reason
This AD was prompted by several incidents of electrical shorting
and sparks caused by de-icing fluid leaks between flight deck
windshields and side windows. We are issuing this AD to detect and
correct de-icing fluid entering the flight deck, which could damage
the flight deck floodlight wires and electrical connections, and
ultimately could lead to a fire in the flight deck compartment.
(f) Compliance
Comply with this AD within the compliance times specified,
unless already done.
(g) Left Flight Deck Windshield and Side Window Spray Test, Inspection,
Water Removal and Sealant Application
For airplanes on which a left flight deck windshield or a left
flight deck side window was replaced as specified in Bombardier
Aircraft Maintenance Manual (AMM) task 56-11-01-400-801, Revision
48, dated March 25, 2015, or any previous revision of that task; or
Bombardier AMM task 56-12-01-400-801, Revision 48, dated March 25,
2015, or any previous revision of that task: At the applicable time
specified in paragraph (g)(1) or (g)(2) of this AD, perform a water
spray test and do a general visual inspection of the left flight
deck windshield and left flight deck side window for evidence of
water ingress into the flight deck, in accordance with Part A of the
Accomplishment Instructions of Bombardier Service Bulletin 670BA-56-
003, Revision A, dated April 13, 2016. If water is found in the
flight deck compartment: Before further flight, remove the water,
and apply sealant on the left flight deck windows in accordance with
Part C of the Accomplishment Instructions of Bombardier Service
Bulletin 670BA-56-003, Revision A, dated April 13, 2016.
(1) For airplanes on which Bombardier in-service ModSum
IS67033110181 has not been incorporated: Within 2,500 flight hours
after the effective date of this AD.
(2) For airplanes on which Bombardier in-service ModSum
IS67033110181 has been incorporated: Within 6,600 flight hours after
the effective date of this AD.
(h) Right Flight Deck Windshield and Side Window Spray Test,
Inspection, Water Removal and Sealant Application
For airplanes on which a right flight deck windshield or a right
flight deck side window was replaced as specified in Bombardier AMM
task 56-11-01-400-801, Revision 48, dated March 25, 2015, or any
previous revision of that task; or Bombardier AMM task 56-12-01-400-
801, Revision 48, dated March 25, 2015, or any previous revision of
that task: At the applicable time specified in paragraph (h)(1) or
(h)(2) of this AD, perform a water spray test and do a general
visual inspection of the right flight deck windshield and right
flight deck side window for evidence of water ingress into the
flight deck, in accordance with Part B of the Accomplishment
Instructions of Bombardier Service Bulletin 670BA-56-003, Revision
A, dated April 13, 2016. If water is found in the flight deck
compartment: Before further flight, remove the water, and apply
sealant on the right flight deck windows in accordance with Part D
of the Accomplishment Instructions of Bombardier Service Bulletin
670BA-56-003, Revision A, dated April 13, 2016.
(1) For airplanes on which Bombardier in-service ModSum
IS67033110181 has not been incorporated: Within 2,500 flight hours
after the effective date of this AD.
(2) For airplanes on which Bombardier in-service ModSum
IS67033110181 has been incorporated: Within 6,600 flight hours after
the effective date of this AD.
(i) Credit for Previous Actions
(1) This paragraph provides credit for actions required by
paragraph (g) of this AD, if those actions were performed before the
effective date of this AD using the service information specified in
paragraphs (i)(1)(i), (i)(1)(ii), or (i)(1)(iii) of this AD;
provided that the left flight deck side window or left flight deck
windshield have not been subsequently replaced as specified in
Bombardier AMM task 56-11-01-400-801, Revision 48, dated March 25,
2015, or any previous revision of that task; or Bombardier AMM task
56-12-01-400-801, Revision 48, dated March 25, 2015, or any previous
revision of that task.
(i) Bombardier Alert Service Bulletin A670BA-56-002, dated
January 7, 2008.
(ii) Bombardier Alert Service Bulletin A670BA-56-002, Revision
A, dated February 26, 2008.
(iii) Part A and Part C, as applicable, of the Accomplishment
Instructions of Bombardier Service Bulletin 670BA-56-003, dated May
28, 2015.
(2) This paragraph provides credit for actions required by
paragraph (h) of this AD, if those actions were performed before the
effective date of this AD using the service information specified in
paragraphs (i)(2)(i), (i)(2)(ii), or (i)(2)(iii) of this AD;
provided that the right flight deck side window or right flight deck
windshield have not been subsequently replaced as specified in
Bombardier AMM task 56-11-01-400-801, Revision 48, dated March 25,
2015, or any previous revision of that task; or Bombardier AMM task
56-12-01-400-801, Revision 48, dated March 25, 2015, or any previous
revision of that task.
(i) Bombardier Alert Service Bulletin A670BA-56-002, dated
January 7, 2008.
(ii) Bombardier Alert Service Bulletin A670BA-56-002, Revision
A, dated February 26, 2008.
(iii) Part B and Part D, as applicable, of the Accomplishment
Instructions of Bombardier Service Bulletin 670BA-56-003, dated May
28, 2015.
(j) Parts Installation Limitations
(1) As of the effective date of this AD, no person may install
on any airplane a left or right flight deck windshield as specified
in Bombardier AMM task 56-11-01-400-801, Revision 48, dated March
25, 2015, or any previous revision of that task.
(2) As of the effective date of this AD, no person may install
on any airplane a left or right flight deck side window as specified
in Bombardier AMM task 56-12-01-400-801, Revision 48, dated March
25, 2015, or any previous revision of that task.
(k) Other FAA AD Provisions
The following provisions also apply to this AD:
(1) Alternative Methods of Compliance (AMOCs): The Manager, New
York ACO Branch, FAA, has the authority to approve AMOCs for this
AD, if requested using the procedures found in 14 CFR 39.19. In
accordance with 14 CFR 39.19, send your request to your principal
inspector or local Flight Standards District Office, as appropriate.
If sending information directly to the manager of the certification
office, send it to ATTN: Program Manager, Continuing Operational
Safety, FAA, New York ACO Branch, 1600 Stewart Avenue, Suite 410,
Westbury, NY 11590; telephone 516-228-7300; fax 516-794-5531. Before
using any approved AMOC, notify your appropriate principal
inspector, or lacking a principal inspector, the manager of the
local flight standards district office/certificate holding district
office.
(2) Contacting the Manufacturer: For any requirement in this AD
to obtain corrective actions from a manufacturer, the action must be
accomplished using a method approved by the Manager, New York ACO
Branch, FAA; or Transport Canada Civil Aviation (TCCA); or
Bombardier, Inc.'s TCCA Design Approval Organization (DAO). If
approved by the DAO, the approval must include the DAO-authorized
signature.
(l) Related Information
(1) Refer to Mandatory Continuing Airworthiness Information
(MCAI) Canadian Airworthiness Directive CF-2017-28, dated August 23,
2017, for related information. This MCAI may be found in the AD
docket on the internet at http://www.regulations.gov by searching
for and locating Docket No. FAA-2017-1025.
(2) For more information about this AD, contact Steven
Dzierzynski, Aerospace Engineer, Avionics and Administrative
Services Section, FAA, New York ACO Branch, 1600 Stewart Avenue,
Suite 410, Westbury, NY 11590; telephone 516-228-7367; fax 516-794-
5531.
(3) Service information identified in this AD that is not
incorporated by reference is available at the addresses specified in
paragraphs (m)(3) and (m)(4) of this AD.
(m) Material Incorporated by Reference
(1) The Director of the Federal Register approved the
incorporation by reference (IBR) of the service information listed
in this paragraph under 5 U.S.C. 552(a) and 1 CFR part 51.
(2) You must use this service information as applicable to do
the actions required by this AD, unless this AD specifies otherwise.
(i) Bombardier Service Bulletin 670BA-56-003, Revision A, dated
April 13, 2016.
(ii) Reserved.
(3) For service information identified in this AD, contact
Bombardier, Inc., 400 C[ocirc]te-Vertu Road West, Dorval,
Qu[eacute]bec H4S 1Y9, Canada; Widebody Customer Response Center
North America toll-free telephone 1-866-538-1247 or direct-dial
telephone 1-514-855-2999; fax 514-855-7401; email
[email protected]; internet http://www.bombardier.com.
[[Page 7975]]
(4) You may view this service information at the FAA, Transport
Standards Branch, 1601 Lind Avenue SW, Renton, WA. For information
on the availability of this material at the FAA, call 425-227-1221.
(5) You may view this service information that is incorporated
by reference at the National Archives and Records Administration
(NARA). For information on the availability of this material at
NARA, call 202-741-6030, or go to: http://www.archives.gov/federal-register/cfr/ibr-locations.html.
Issued in Renton, Washington, on February 9, 2018.
Michael Kaszycki,
Acting Director, System Oversight Division, Aircraft Certification
Service.
[FR Doc. 2018-03438 Filed 2-22-18; 8:45 am]
BILLING CODE 4910-13-P
Why this text is shown
The complete text was extracted from the official GovInfo HTML edition for this publication. Acquired 2026-10-09T02:15:48.303014+00:00. Text extraction preserves the recorded source wording; it does not determine current requirements.
Open the captured official edition
- Source SHA-256
- 251a00620e2cecdc63917063a43055c1e000dc61db4f722e08983168dc4ebba5
- Text SHA-256
- db586b5ef685ed673683aec99e8ba6f9da976875963943d1ffa23f42d715aa3c
Return to the full metadata catalog · Search complete publication text · Explore retained publication text and evidence
Coverage and limits
These are dated publication metadata, recorded clauses and literal source observations. Word, model-label, header and reference matches do not establish current legal effect, manufacturer/model identity, aircraft applicability, installed configuration or compliance.
The collection uses 33 explicit annual source snapshots. Source captures and operative-text qualifications have separate states. Missing information remains unknown.