Back to publication catalog

Published 2020-02-13 · Federal Register document 2020-02841

Airworthiness Directives; Airbus Helicopters

Publication summary

The FAA is adopting a new airworthiness directive (AD) for certain Airbus Helicopters Model AS350B, AS350BA, AS350B1, AS350B2, AS350B3, AS350C, AS350D, A350D1, AS355E, AS355F, AS355F1, AS355F2, AS355N, and AS355NP helicopters. This AD requires repetitive inspections of the installation of the pull cables on the emergency float kits. This AD was prompted by the results of an accident investigation and subsequent reports of difficulty pulling the emergency float kit float activation handle installed on the pilot cyclic. The FAA is issuing this AD to address the unsafe condition on these products.

Why this record is shown

Source: Federal Register annual FAA metadata. Acquired 2026-09-03T22:24:04.586324+00:00. The title, summary and date are source facts.

Source revision
federal_register_ad_metadata_2020-f01fbc4d7ab3dbaa
Source row
results[37]
Raw source SHA-256
f01fbc4d7ab3dbaae6a412acd9ff6cece48db77a6a882e46e8f8087200be3837

Final-rule publication

Recorded publication clauses

AD identifier printed in this edition
2020-02-23
Effective date printed in this edition
2020-02-28
Read 11 complete recorded clauses
Effective Date
(a) Effective Date

    This AD is effective February 28, 2020.

Exact source excerpt. Text positions 15301–15366, end exclusive, in the original decoded publication. SHA-256: 2d92294e16ef41430dc7bd49005f04a122b5587de492e92fb0aa664f205a0347

Affected ADs
(b) Affected ADs

    None.

Exact source excerpt. Text positions 15366–15395, end exclusive, in the original decoded publication. SHA-256: 871a4afc60ceeae06e8010585055188633d616078500c45937092bfe892239c0

Applicability wording · Applicability
(c) Applicability

    This AD applies to the helicopters identified in paragraphs 
(c)(1) and (2) of this AD, certificated in any category.
    (1) Airbus Helicopters Model AS350B, AS350BA, AS350B1, AS350B2, 
AS350B3, AS350C, AS350D, and AS350D1 helicopters, modified by 
supplemental type certificate (STC) SR00470LA.
    (2) Airbus Helicopters Model AS355E, AS355F, AS355F1, AS355F2, 
AS355N, and AS355NP helicopters, modified by STC SR00645LA.

Exact source excerpt. Text positions 15395–15844, end exclusive, in the original decoded publication. SHA-256: c554e6b986b6701858f4e6882da83aaf2ba361cd4172cc6342660398b448d9d5

Subject
(d) Subject

    Air Transport Association (ATA) of America Code 25, Equipment/
Furnishings, and 32, Landing gear.

Exact source excerpt. Text positions 15844–15960, end exclusive, in the original decoded publication. SHA-256: 891a99b49c7b0bff0d809d0ba03aa315fe3542b7a52a6b3379a484e3163478fd

Unsafe Condition
(e) Unsafe Condition

    This AD was prompted by reports of difficulty pulling the 
emergency float kit float activation handle installed on the pilot 
cyclic. The FAA is issuing this AD to address improperly installed 
pull cables, which can lead to difficulty deploying the float system 
from the float activation handle installed on the pilot cyclic, and 
could result in loss of the left- or right-hand float, causing the 
helicopter to roll to one side but remain buoyant, or loss of both 
floats causing the helicopter to capsize underwater.

Exact source excerpt. Text positions 15960–16510, end exclusive, in the original decoded publication. SHA-256: d11a39c5136ecc23c8271eff60b41e3235086471d43fdc13da5d6443500ab43c

Compliance
(f) Compliance

    Comply with this AD within the compliance times specified, 
unless already done.

Exact source excerpt. Text positions 16510–16612, end exclusive, in the original decoded publication. SHA-256: 00fbfa31932483f627d0ce0a11cbd2e35e15d9231842b91ac85623ce533912d3

Required Actions
(g) Required Actions

    Within 100 hours time-in-service (TIS) or 30 days, whichever 
occurs first after the effective date of this AD, and thereafter at 
intervals not to exceed six months, inspect the installation of the 
pull cables on the emergency float kit and readjust the cable 
rigging if improperly installed, in accordance with the 
Accomplishment Instructions, sections 1.0 through 1.4, of DART 
Aerospace Service Bulletin No. SB-2018-07, Revision D, dated 
November 25, 2019 (``SB-2018-07, Revision D''), except if the pull 
cable installation does not pass the test in section 1.3 after re-
adjusting the cable rigging, you must comply with either paragraph 
(g)(1) or (2) of this AD before further flight:
    (1) Repair the pull cable installation.
    (2) Deactivate and placard the emergency float system as 
inoperative in accordance with the Accomplishment Instructions, 
section 3.0, of SB-2018-07, Revision D. If the emergency float 
system has been deactivated and placarded as inoperative, you are 
not required to repeat the inspection specified in the introductory 
text of paragraph (g) of this AD.

    Note 1 to paragraph (g)(2) of this AD:  This AD does not allow 
operation with an inoperative emergency float system unless the 
requirements of 14 CFR 91.213 have been met.

Exact source excerpt. Text positions 16612–17920, end exclusive, in the original decoded publication. SHA-256: c98e32b90159869e100820bc0fb54f26f3970e139f144aef556b92f89ea95000

Credit for Previous Actions
(h) Credit for Previous Actions

    This paragraph provides credit for the actions specified in 
introductory text of paragraph (g) and paragraph (g)(2) of this AD, 
if the actions were done before the effective date of this AD using 
DART Aerospace Service Bulletin SB-2018-07, Revision B, dated 
October 8, 2019, or DART Aerospace Service Bulletin SB-2018-07, 
Revision C, dated November 14, 2019.

Exact source excerpt. Text positions 17920–18322, end exclusive, in the original decoded publication. SHA-256: ae96c17cf7a300f96c5407936cde875d0bbd89b4b9e2c44c7c6e369e8a2bca3f

Alternative Methods of Compliance (AMOCs)
(i) Alternative Methods of Compliance (AMOCs)

    (1) The Manager, Los Angeles ACO Branch, FAA, has the authority 
to approve AMOCs for this AD, if requested using the procedures 
found in 14 CFR 39.19. In accordance with 14 CFR 39.19, send your 
request to your principal inspector or local Flight Standards 
District Office, as appropriate. If sending information directly to 
the manager of the certification office, send it to the attention of 
the person identified in paragraph (j) of this AD. Information may 
be emailed to: [email protected].
    (2) For operations conducted under a 14 CFR part 119 operating 
certificate or under 14 CFR part 91, subpart K, notify your 
principal inspector or lacking a principal inspector, the manager of 
the local flight standards district office or certificate holding 
district office, before operating any aircraft complying with this 
AD through an AMOC.

Exact source excerpt. Text positions 18322–19229, end exclusive, in the original decoded publication. SHA-256: ff9e32ecd3a23f8646f0af7b6bf4003d0834a4a7a90ee338e56d11c826fbe36e

Related Information
(j) Related Information

    For information about AMOCs, contact Johann S. Magana, Aerospace 
Engineer, Cabin Safety and Environmental Systems Section, FAA, Los 
Angeles ACO Branch, 3960 Paramount Boulevard, Lakewood, CA 90712-
4137; phone: 562-627-5322; fax: 562-627-5210; email: 
[email protected].

Exact source excerpt. Text positions 19229–19532, end exclusive, in the original decoded publication. SHA-256: a2df82652e16565b42584cbd394be760a787f123ba61c19f339a0545136adc4f

Material Incorporated by Reference
(k) Material Incorporated by Reference

    (1) The Director of the Federal Register approved the 
incorporation by reference (IBR) of the service information listed 
in this paragraph under 5 U.S.C. 552(a) and 1 CFR part 51.
    (2) You must use this service information as applicable to do 
the actions required by this AD, unless the AD specifies otherwise.

[[Page 8153]]

    (i) DART Aerospace Service Bulletin SB-2018-07, Revision D, 
dated November 25, 2019.
    (ii) [Reserved]
    (3) For service information identified in this AD, contact Dart 
Aerospace LTD., 1270 Aberdeen St., Hawkesbury, ON, K6A 1K7, Canada; 
telephone: 1-613-632-5200; Fax: 1-613-632-5246; or at 
www.dartaero.com.
    (4) You may view this service information at the FAA, Office of 
the Regional Counsel, Southwest Region, 10101 Hillwood Pkwy., Room 
6N-321, Fort Worth, TX 76177. For information on the availability of 
this material at the FAA, call 817-222-5110.
    (5) You may view this service information that is incorporated 
by reference at the National Archives and Records Administration 
(NARA). For information on the availability of this material at 
NARA, email [email protected], or go to: https://www.archives.gov/federal-register/cfr/ibr-locations.html.

Exact source excerpt. Text positions 19532–20789, end exclusive, in the original decoded publication. SHA-256: 3f43d3ad06a442ec7ecba50111435bd03282cc298bb7671c8983a520f5fec3fe

No replacement link has been established from this edition. The complete historical rule chain and current legal effect remain unknown.

Find all recorded historical references to AD 2020-02-23 · 0 printed reference observations in this pinned collection.

These are observations from one dated publication. Current legal status is unknown; aircraft applicability, installed configuration, compliance and burden require separate evidence. Missing or unparsed conditions remain unknown.

Why these observations are shown

They were extracted offline from the same immutable official HTML source as the complete recorded text. The dated source wording, original text coordinates and exact quote digests are retained. PDF/text agreement and current regulatory effect have not been qualified.

Observation revision: whole-ad-publication-clause-observations-1.0.1. Text SHA-256: 659447aca10d92ca1895c90f6043aed27cdf96c764ad05484ae1cedba218310e. Source manifest: b383ec701999cdc9a37245ccf7f01d78e7f3a5addfeebf3ec5e2a4488bc71dcd.

Official source · 2020-02-13

Publication text

This is the complete recorded text of this dated publication.

Current legal effect is unknown. Aircraft applicability, installed configuration and compliance require separate evidence. PDF/text agreement has not been evaluated.

Read the complete official publication text
[Federal Register Volume 85, Number 30 (Thursday, February 13, 2020)]
[Rules and Regulations]
[Pages 8150-8153]
From the Federal Register Online via the Government Publishing Office [www.gpo.gov]
[FR Doc No: 2020-02841]


-----------------------------------------------------------------------

DEPARTMENT OF TRANSPORTATION

Federal Aviation Administration

14 CFR Part 39

[Docket No. FAA-2020-0125; Product Identifier 2019-SW-104-AD; Amendment 
39-21027; AD 2020-02-23]
RIN 2120-AA64


Airworthiness Directives; Airbus Helicopters

AGENCY: Federal Aviation Administration (FAA), DOT.

ACTION: Final rule; request for comments.

-----------------------------------------------------------------------

SUMMARY: The FAA is adopting a new airworthiness directive (AD) for 
certain Airbus Helicopters Model AS350B, AS350BA, AS350B1, AS350B2, 
AS350B3, AS350C, AS350D, A350D1, AS355E, AS355F, AS355F1, AS355F2, 
AS355N, and AS355NP helicopters. This AD requires repetitive 
inspections of the installation of the pull cables on the emergency 
float kits. This AD was prompted by the results of an accident 
investigation and subsequent reports of difficulty pulling the 
emergency float kit float activation handle installed on the pilot 
cyclic. The FAA is issuing this AD to address the unsafe condition on 
these products.

DATES: This AD is effective February 28, 2020.
    The Director of the Federal Register approved the incorporation by 
reference of a certain publication listed in this AD as of February 28, 
2020.
    The FAA must receive comments on this AD by March 30, 2020.

ADDRESSES: You may send comments, using the procedures found in 14 CFR 
11.43 and 11.45, by any of the following methods:
    <bullet> Federal eRulemaking Portal: Go to https://www.regulations.gov. Follow the instructions for submitting comments.
    <bullet> Fax: 202-493-2251.
    <bullet> Mail: U.S. Department of Transportation, Docket 
Operations, M-30, West Building Ground Floor, Room W12-140, 1200 New 
Jersey Avenue SE, Washington, DC 20590.
    <bullet> Hand Delivery: Deliver to Mail address above between 9 
a.m. and 5 p.m., Monday through Friday, except Federal holidays.
    For service information identified in this final rule, contact Dart 
Aerospace LTD., 1270 Aberdeen St., Hawkesbury, ON, K6A 1K7, Canada; 
telephone: 1-613-632-5200; Fax: 1-613-632-5246; or at www.dartaero.com.
    You may view this service information at the FAA, Office of the 
Regional Counsel, Southwest Region, 10101 Hillwood Pkwy, Room 6N-321, 
Fort Worth, TX 76177. For information on the availability of this 
material at the FAA, call 817-222-5110.
    It is also available on the internet at https://www.regulations.gov 
by searching for and locating Docket No. FAA-2020-0125.

Examining the AD Docket

    You may examine the AD docket on the internet at https://www.regulations.gov by searching for and locating Docket No. FAA-2020-
0125; or in person at Docket Operations between 9 a.m. and 5 p.m., 
Monday through Friday, except Federal holidays. The AD docket contains 
this final rule, the regulatory evaluation, any comments received, and 
other information. The street address for Docket Operations is listed 
above. Comments will be available in the AD docket shortly after 
receipt.

FOR FURTHER INFORMATION CONTACT: Johann S. Magana, Aerospace Engineer, 
Cabin Safety and Environmental Systems Section, FAA, Los Angeles ACO 
Branch, 3960 Paramount Boulevard, Lakewood, CA 90712-4137; phone: 562-
627-5322; fax: 562-627-5210; email: [email protected].

SUPPLEMENTARY INFORMATION: 

Discussion

    This AD is prompted by the results of an investigation of a March 
11, 2018, fatal accident in which an Airbus Helicopters Model AS350B2 
helicopter impacted a body of water during an autorotation. The left-
hand and right-hand emergency floats did not inflate symmetrically and 
the helicopter subsequently capsized.
    During the accident investigation, the FAA learned of reports of 
difficulty pulling the emergency float kit float activation handle 
installed on the pilot cyclic. Asymmetric inflation of the float system 
and difficulty deploying the float system from the float activation 
handle installed on the pilot cyclic can be caused by improperly 
installed pull cables. These emergency float kits utilize a system of 
pull cables to activate and release compressed gas from the float 
cylinders into the floats. Proper installation of the pull cables 
allows the two float cylinders installed on the aircraft to activate 
simultaneously, allowing for proper distribution of gas to all floats 
in the system. Improperly installed pull cables, if not addressed, 
could result in loss of the left- or right-hand float, causing the 
helicopter to roll to one side but remain buoyant, or loss of both 
floats, causing the helicopter to capsize underwater.
    These emergency float systems are installed on Airbus Helicopters 
Model AS350B, AS350BA, AS350B1, AS350B2, AS350B3, AS350C, AS350D, and 
AS350D1 helicopters under Supplemental Type Certificate (STC) 
SR00470LA, and on Model AS355E, AS355F, AS355F1, AS355F2, AS355N, and 
AS355NP helicopters under STC SR00645LA. Both STCs are held by Apical 
Industries, Inc., d/b/a DART Aerospace (DART). Following the 
investigation, DART developed a test tool to verify correct 
installation and rigging of the pull cables and subsequently issued 
service information to provide instructions for using the test tool. 
The FAA approved these instructions to correct the unsafe condition on 
November 13, 2019. Accordingly, the FAA is issuing this AD to address 
the unsafe condition on these products.

[[Page 8151]]

Related Service Information Under 1 CFR Part 51

    The FAA has reviewed DART Aerospace Service Bulletin SB-2018-07, 
Revision D, dated November 25, 2019. This service information contains 
procedures for inspecting the installation of the pull cables on 20326-
series part-numbered emergency float kits (e.g., inspecting for 
activation pull forces on the float activation handle), readjusting the 
cable rigging if improperly installed, and contacting DART if 
readjusting the rigging is not successful. This service information 
also contains optional procedures for deactivating the emergency float 
system as inoperative.
    This service information is reasonably available because the 
interested parties have access to it through their normal course of 
business or by the means identified in the ADDRESSES section.

Other Related Service Information

    The FAA has also reviewed DART Aerospace Service Bulletin SB-2018-
07, Revision B, dated October 8, 2019, and DART Aerospace Service 
Bulletin SB-2018-07, Revision C, dated November 14, 2019. The actions 
specified in these service bulletins are the same as those specified in 
DART Aerospace Service Bulletin SB-2018-07, Revision D, dated November 
25, 2019. DART Aerospace Service Bulletin SB-2018-07, Revision C, dated 
November 14, 2019, adds a note that includes a reference to the 
instructions for continued airworthiness for a specific float system 
configuration that was not in DART Aerospace Service Bulletin SB-2018-
07, Revision B, dated October 8, 2019. DART Aerospace Service Bulletin 
SB-2018-07, Revision D, dated November 25, 2019, clarifies certain 
references to the operational instructions manual. These differences do 
not affect how operators would accomplish the actions necessary to 
address the identified unsafe condition.

FAA's Determination

    The FAA is issuing this AD after evaluating all the relevant 
information and determining the unsafe condition described previously 
is likely to exist or develop in other products of the same type 
design.

AD Requirements

    This AD requires repetitive inspections of the installation of the 
pull cables on the emergency float kits and corrective action if 
necessary.

Differences Between This AD and the Service Information

    DART Aerospace Service Bulletin SB-2018-07, Revision D, dated 
November 25, 2019, specifies accomplishing the actions before March 31, 
2020, while this AD requires compliance within 100 hours time-in-
service (TIS) or 30 days after the effective date of this AD, whichever 
occurs first.

FAA's Justification and Determination of the Effective Date

    Section 553(b)(3)(B) of the Administrative Procedure Act (5 U.S.C.) 
authorizes agencies to dispense with notice and comment procedures for 
rules when the agency, for ``good cause'' finds that those procedures 
are ``impracticable, unnecessary, or contrary to the public interest.'' 
Under this section, an agency, upon finding good cause, may issue a 
final rule without seeking comment prior to the rulemaking.
    An unsafe condition exists that requires the immediate adoption of 
this AD without providing an opportunity for public comments prior to 
adoption. The FAA has found that the risk to the flying public 
justifies waiving notice and comment prior to adoption of this rule 
because improperly installed pull cables may lead to asymmetric 
inflation of the float system or difficulty deploying the float system 
from the float activation handle installed on the pilot cyclic, which 
could result in the loss of one or more floats. Loss of the left- or 
right-hand float could cause the helicopter to roll to one side but 
remain buoyant, while loss of both floats could cause the helicopter to 
capsize underwater. Because of the high utilization rate of helicopters 
with these emergency float kits installed, and because these 
helicopters primarily conduct operations over water, the FAA determined 
a compliance time of no more than 100 hours TIS or 30 days, whichever 
occurs first, was required to correct the unsafe condition. This 
compliance time is shorter than the time necessary for the public to 
comment and for publication of the final rule. Therefore, notice and 
opportunity for prior public comment are impracticable and contrary to 
public interest pursuant to 5 U.S.C. 553(b)(3)(B). In addition, for the 
reasons stated above, the FAA finds that good cause exists pursuant to 
5 U.S.C. 553(d) for making this amendment effective in less than 30 
days.

Comments Invited

    This AD is a final rule that involves requirements affecting flight 
safety and was not preceded by notice and an opportunity for public 
comment. However, the FAA invites you to send any written data, views, 
or arguments about this final rule. Send your comments to an address 
listed under the ADDRESSES section. Include the docket number FAA-2020-
0125 and Product Identifier 2019-SW-104-AD at the beginning of your 
comments. The FAA specifically invites comments on the overall 
regulatory, economic, environmental, and energy aspects of this final 
rule. The FAA will consider all comments received by the closing date 
and may amend this final rule because of those comments.
    The FAA will post all comments received, without change, to https://www.regulations.gov, including any personal information you provide. 
The FAA will also post a report summarizing each substantive verbal 
contact received about this final rule.

Regulatory Flexibility Act

    The requirements of the Regulatory Flexibility Act (RFA) do not 
apply when an agency finds good cause pursuant to 5 U.S.C. 553 to adopt 
a rule without prior notice and comment. Because FAA has determined 
that it has good cause to adopt this rule without notice and comment, 
RFA analysis is not required.

Costs of Compliance

    The FAA estimates that this AD affects 71 helicopters of U.S. 
registry. The FAA estimates the following costs to comply with this AD:

                                                 Estimated Costs
----------------------------------------------------------------------------------------------------------------
                                                                                     Cost per      Cost on U.S.
               Action                         Labor cost            Parts cost      helicopter       operators
----------------------------------------------------------------------------------------------------------------
Inspection.........................  3 work-hours x $85 per hour              $0            $255         $18,105
                                      = $255 per inspection.
----------------------------------------------------------------------------------------------------------------


[[Page 8152]]

    The inspection requires the use of a pull cable test kit, which 
costs $2,000. Only one pull cable test kit is needed per operator such 
that the operator may use the same pull cable test kit on any affected 
helicopter. The FAA has no way of determining what on-condition actions 
may be required following the inspection required by this AD, the 
number of helicopters that might need on-condition actions, or the 
costs to perform the on-condition actions.
    According to the manufacturer, some or all of the costs of this AD 
may be covered under warranty, thereby reducing the cost impact on 
affected individuals. The FAA does not control warranty coverage for 
affected individuals. As a result, the FAA has included all known costs 
in the cost estimate.

Authority for This Rulemaking

    Title 49 of the United States Code specifies the FAA's authority to 
issue rules on aviation safety. Subtitle I, section 106, describes the 
authority of the FAA Administrator. Subtitle VII: Aviation Programs 
describes in more detail the scope of the Agency's authority.
    The FAA is issuing this rulemaking under the authority described in 
Subtitle VII, Part A, Subpart III, Section 44701: General requirements. 
Under that section, Congress charges the FAA with promoting safe flight 
of civil aircraft in air commerce by prescribing regulations for 
practices, methods, and procedures the Administrator finds necessary 
for safety in air commerce. This regulation is within the scope of that 
authority because it addresses an unsafe condition that is likely to 
exist or develop on products identified in this rulemaking action.

Regulatory Findings

    This AD will not have federalism implications under Executive Order 
13132. This AD will not have a substantial direct effect on the States, 
on the relationship between the national government and the States, or 
on the distribution of power and responsibilities among the various 
levels of government.
    For the reasons discussed above, I certify that this AD:
    (1) Is not a ``significant regulatory action'' under Executive 
Order 12866, and
    (2) Will not affect intrastate aviation in Alaska.

List of Subjects in 14 CFR Part 39

    Air transportation, Aircraft, Aviation safety, Incorporation by 
reference, Safety.

Adoption of the Amendment

    Accordingly, under the authority delegated to me by the 
Administrator, the FAA amends 14 CFR part 39 as follows:

PART 39--AIRWORTHINESS DIRECTIVES

0
1. The authority citation for part 39 continues to read as follows:

    Authority:  49 U.S.C. 106(g), 40113, 44701.


Sec.  39.13   [Amended]

0
2. The FAA amends Sec.  39.13 by adding the following new airworthiness 
directive (AD):

2020-02-23 Airbus Helicopters: Amendment 39-21027; Docket No. FAA-
2020-0125; Product Identifier 2019-SW-104-AD.

(a) Effective Date

    This AD is effective February 28, 2020.

(b) Affected ADs

    None.

(c) Applicability

    This AD applies to the helicopters identified in paragraphs 
(c)(1) and (2) of this AD, certificated in any category.
    (1) Airbus Helicopters Model AS350B, AS350BA, AS350B1, AS350B2, 
AS350B3, AS350C, AS350D, and AS350D1 helicopters, modified by 
supplemental type certificate (STC) SR00470LA.
    (2) Airbus Helicopters Model AS355E, AS355F, AS355F1, AS355F2, 
AS355N, and AS355NP helicopters, modified by STC SR00645LA.

(d) Subject

    Air Transport Association (ATA) of America Code 25, Equipment/
Furnishings, and 32, Landing gear.

(e) Unsafe Condition

    This AD was prompted by reports of difficulty pulling the 
emergency float kit float activation handle installed on the pilot 
cyclic. The FAA is issuing this AD to address improperly installed 
pull cables, which can lead to difficulty deploying the float system 
from the float activation handle installed on the pilot cyclic, and 
could result in loss of the left- or right-hand float, causing the 
helicopter to roll to one side but remain buoyant, or loss of both 
floats causing the helicopter to capsize underwater.

(f) Compliance

    Comply with this AD within the compliance times specified, 
unless already done.

(g) Required Actions

    Within 100 hours time-in-service (TIS) or 30 days, whichever 
occurs first after the effective date of this AD, and thereafter at 
intervals not to exceed six months, inspect the installation of the 
pull cables on the emergency float kit and readjust the cable 
rigging if improperly installed, in accordance with the 
Accomplishment Instructions, sections 1.0 through 1.4, of DART 
Aerospace Service Bulletin No. SB-2018-07, Revision D, dated 
November 25, 2019 (``SB-2018-07, Revision D''), except if the pull 
cable installation does not pass the test in section 1.3 after re-
adjusting the cable rigging, you must comply with either paragraph 
(g)(1) or (2) of this AD before further flight:
    (1) Repair the pull cable installation.
    (2) Deactivate and placard the emergency float system as 
inoperative in accordance with the Accomplishment Instructions, 
section 3.0, of SB-2018-07, Revision D. If the emergency float 
system has been deactivated and placarded as inoperative, you are 
not required to repeat the inspection specified in the introductory 
text of paragraph (g) of this AD.

    Note 1 to paragraph (g)(2) of this AD:  This AD does not allow 
operation with an inoperative emergency float system unless the 
requirements of 14 CFR 91.213 have been met.

(h) Credit for Previous Actions

    This paragraph provides credit for the actions specified in 
introductory text of paragraph (g) and paragraph (g)(2) of this AD, 
if the actions were done before the effective date of this AD using 
DART Aerospace Service Bulletin SB-2018-07, Revision B, dated 
October 8, 2019, or DART Aerospace Service Bulletin SB-2018-07, 
Revision C, dated November 14, 2019.

(i) Alternative Methods of Compliance (AMOCs)

    (1) The Manager, Los Angeles ACO Branch, FAA, has the authority 
to approve AMOCs for this AD, if requested using the procedures 
found in 14 CFR 39.19. In accordance with 14 CFR 39.19, send your 
request to your principal inspector or local Flight Standards 
District Office, as appropriate. If sending information directly to 
the manager of the certification office, send it to the attention of 
the person identified in paragraph (j) of this AD. Information may 
be emailed to: [email protected].
    (2) For operations conducted under a 14 CFR part 119 operating 
certificate or under 14 CFR part 91, subpart K, notify your 
principal inspector or lacking a principal inspector, the manager of 
the local flight standards district office or certificate holding 
district office, before operating any aircraft complying with this 
AD through an AMOC.

(j) Related Information

    For information about AMOCs, contact Johann S. Magana, Aerospace 
Engineer, Cabin Safety and Environmental Systems Section, FAA, Los 
Angeles ACO Branch, 3960 Paramount Boulevard, Lakewood, CA 90712-
4137; phone: 562-627-5322; fax: 562-627-5210; email: 
[email protected].

(k) Material Incorporated by Reference

    (1) The Director of the Federal Register approved the 
incorporation by reference (IBR) of the service information listed 
in this paragraph under 5 U.S.C. 552(a) and 1 CFR part 51.
    (2) You must use this service information as applicable to do 
the actions required by this AD, unless the AD specifies otherwise.

[[Page 8153]]

    (i) DART Aerospace Service Bulletin SB-2018-07, Revision D, 
dated November 25, 2019.
    (ii) [Reserved]
    (3) For service information identified in this AD, contact Dart 
Aerospace LTD., 1270 Aberdeen St., Hawkesbury, ON, K6A 1K7, Canada; 
telephone: 1-613-632-5200; Fax: 1-613-632-5246; or at 
www.dartaero.com.
    (4) You may view this service information at the FAA, Office of 
the Regional Counsel, Southwest Region, 10101 Hillwood Pkwy., Room 
6N-321, Fort Worth, TX 76177. For information on the availability of 
this material at the FAA, call 817-222-5110.
    (5) You may view this service information that is incorporated 
by reference at the National Archives and Records Administration 
(NARA). For information on the availability of this material at 
NARA, email [email protected], or go to: https://www.archives.gov/federal-register/cfr/ibr-locations.html.

    Issued on February 7, 2020.
Lance T. Gant,
Director, Compliance & Airworthiness Division, Aircraft Certification 
Service.
[FR Doc. 2020-02841 Filed 2-12-20; 8:45 am]
 BILLING CODE 4910-13-P


Why this text is shown

The complete text was extracted from the official GovInfo HTML edition for this publication. Acquired 2026-10-09T02:04:01.824141+00:00. Text extraction preserves the recorded source wording; it does not determine current requirements.

Open the captured official edition

Source SHA-256
692458dcb6677b2748a03bb2449d0685eb399e82e29f97501a1dbe29bb533735
Text SHA-256
659447aca10d92ca1895c90f6043aed27cdf96c764ad05484ae1cedba218310e

Return to the full metadata catalog · Search complete publication text · Explore retained publication text and evidence

Coverage and limits

These are dated publication metadata, recorded clauses and literal source observations. Word, model-label, header and reference matches do not establish current legal effect, manufacturer/model identity, aircraft applicability, installed configuration or compliance.

The collection uses 33 explicit annual source snapshots. Source captures and operative-text qualifications have separate states. Missing information remains unknown.