Published 2006-08-09 · Federal Register document E6-12829
Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes
Publication summary
The FAA is adopting a new airworthiness directive (AD) for certain Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) airplanes. This AD requires inspecting contactors 1K4XD, 2K4XD, and K4XA to determine the type of terminal base plate, and applying sealant on the terminal base plates, if necessary. This AD results from incidents of short circuit failures of certain alternating current (AC) contactors located in the avionics bay. We are issuing this AD to prevent short circuit failures of certain AC contactors, which could result in arcing and consequent smoke or fire.
Why this record is shown
Source: Federal Register annual FAA metadata. Acquired 2026-09-03T22:23:20.745856+00:00. The title, summary and date are source facts.
- Source revision
- federal_register_ad_metadata_2006-8d787f8b35bc8016
- Source row
- results[280]
- Raw source SHA-256
- 8d787f8b35bc80165a417cea66de09cd32a1700face13759db364c607e405963
Final-rule publication
Recorded publication clauses
- AD identifier printed in this edition
- 2006-16-07
- Effective date printed in this edition
- 2006-08-09
Read 10 complete recorded clauses
Effective Date
Effective Date
(a) This AD becomes effective August 9, 2006.
Exact source excerpt. Text positions 11372–11439, end exclusive, in the original decoded publication. SHA-256: 34b7683d1efc009adc0a33441230805e8c24628869cd34b1ba1a59cee624fdaf
Affected ADs
Affected ADs
(b) None.
Exact source excerpt. Text positions 11439–11468, end exclusive, in the original decoded publication. SHA-256: 027fbc44617399472b6ac4741da3aee18448654374228bcf4fe3f01df6b1539b
Applicability wording · Applicability
Applicability
(c) This AD applies to Bombardier Model CL-600-2B19 (Regional
Jet Series 100 & 440) airplanes, certificated in any category,
serial numbers 7003 through 7990 inclusive and 8000 and subsequent.
Exact source excerpt. Text positions 11468–11683, end exclusive, in the original decoded publication. SHA-256: 60da331871c4accb34d27d3bed034987653a5083b9864b2acace35e8bdff15fe
Unsafe Condition
Unsafe Condition
(d) This AD results from incidents of short circuit failures of
certain alternating current (AC) contactors located in the avionics
bay. We are issuing this AD to prevent short circuit failures of
certain AC contactors, which could result in arcing and consequent
smoke or fire.
Exact source excerpt. Text positions 11683–11989, end exclusive, in the original decoded publication. SHA-256: 08b7dac60f220214aae05d5c318f3fba852da410548955a58a34064bb6ea4ff2
Compliance
Compliance
(e) You are responsible for having the actions required by this
AD performed within the compliance times specified, unless the
actions have already been done.
Exact source excerpt. Text positions 11989–12167, end exclusive, in the original decoded publication. SHA-256: 64a7a1579f37f56eafecd0aeb3c528e7c89f6292ed0cb53091423917642d5847
Inspection and Corrective Action
Inspection and Corrective Action
(f) Within 800 flight hours or four months after the effective
date of this AD, whichever occurs first: Do a general visual
inspection of AC service bus contactors 1K4XD and 2K4XD, part number
(P/N) D-18ZZA, and the utility bus contactor K4XA, P/N D-7GRZ, to
determine which contactors have an Ultem 2200 terminal base plate
(i.e., the plate is made from a black molded thermal plastic
material), and apply RTV sealant to the terminal base plate, as
applicable, by doing all the actions specified in the Accomplishment
Instructions of Bombardier Service Bulletin 601R-24-122, Revision A,
dated July 13, 2006. Do all applicable applications of sealant
before further flight.
Note 1: For the purposes of this AD, a general visual inspection
is: ``A visual examination of an interior or exterior area,
installation, or assembly to detect obvious damage, failure, or
irregularity. This level of inspection is made from within touching
distance unless otherwise specified. A mirror may be necessary to
ensure visual access to all surfaces in the inspection area. This
level of inspection is made under normally available lighting
conditions such as daylight, hangar lighting, flashlight, or
droplight and may require removal or opening of access panels or
doors. Stands, ladders, or platforms may be required to gain
proximity to the area being checked.''
Exact source excerpt. Text positions 12167–13584, end exclusive, in the original decoded publication. SHA-256: d06a136abdd575877aeb85bfd43c6bd325d2979c7923476f29940ef6c1858dd5
Previous Actions Accomplished According to Other Service Information
Previous Actions Accomplished According to Other Service Information
(g) Actions accomplished before the effective date of this AD in
accordance with Bombardier Drawing Number K601R50180, dated June 2,
2006; or Bombardier Service Bulletin 601R-24-122, dated June 27,
2006; are considered acceptable for compliance with the actions
specified in paragraph (f) of this AD.
Exact source excerpt. Text positions 13584–13964, end exclusive, in the original decoded publication. SHA-256: 1929bc5261553c1ede9c49fd90e3027e26e29f38bb3d55d8d3a51264bc23113c
Parts Installation
Parts Installation
(h) As of the effective date of this AD, no person may install
AC contactor 1K4XD, 2K4XD, or K4XA, having an Ultem 2200 terminal
base plate, on any airplane, unless RTV sealant has been applied to
the terminal base plate in accordance with Bombardier Service
Bulletin 601R-24-122, Revision A, dated July 13, 2006.
Alternative Methods of Compliance (AMOCs)
(i)(1) The Manager, New York Aircraft Certification Office, FAA,
has the authority to approve AMOCs for this AD, if requested in
accordance with the procedures found in 14 CFR 39.19.
(2) Before using any AMOC approved in accordance with Sec.
39.19 on any airplane to which the AMOC applies, notify the
appropriate principal inspector in the FAA Flight Standards
Certificate Holding District Office.
Exact source excerpt. Text positions 13964–14764, end exclusive, in the original decoded publication. SHA-256: 1fdc7ad8b738a555ecb24ae37cfe4b6e34566c84bcb3fee7633777b504e50192
Related Information
Related Information
(j) Canadian airworthiness directive CF-2006-17, dated July 11,
2006, also addresses the subject of this AD.
Exact source excerpt. Text positions 14764–14900, end exclusive, in the original decoded publication. SHA-256: 20904bcacb0c76be2f87a616f074f85fcca483c98dd81204bc017880d330a0ae
Material Incorporated by Reference
Material Incorporated by Reference
(k) You must use Bombardier Service Bulletin 601R-24-122,
Revision A, dated July 13, 2006, to perform the actions that are
required by this AD, unless the AD specifies otherwise. The Director
of the Federal Register approved the incorporation by reference of
this document in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.
Contact Bombardier, Inc., Canadair, Aerospace Group, P.O. Box 6087,
Station Centre-ville, Montreal, Quebec H3C 3G9, Canada, for a copy
of this service information. You may review copies at the Docket
Management Facility, U.S. Department of Transportation, 400 Seventh
Street SW., Room PL-401, Nassif Building, Washington, DC; on the
Internet at http://dms.dot.gov; or at the National Archives and
Records Administration (NARA). For information on the availability
of this material at the NARA, call (202) 741-6030, or go to http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html.
[[Page 45367]]
Exact source excerpt. Text positions 14900–15909, end exclusive, in the original decoded publication. SHA-256: e4521747b8716a84946dee3e464fac78b73b37e3915382980ec432ba3f1f2e45
No replacement link has been established from this edition. The complete historical rule chain and current legal effect remain unknown.
Find all recorded historical references to AD 2006-16-07 · 0 printed reference observations in this pinned collection.
These are observations from one dated publication. Current legal status is unknown; aircraft applicability, installed configuration, compliance and burden require separate evidence. Missing or unparsed conditions remain unknown.
Why these observations are shown
They were extracted offline from the same immutable official HTML source as the complete recorded text. The dated source wording, original text coordinates and exact quote digests are retained. PDF/text agreement and current regulatory effect have not been qualified.
Observation revision: whole-ad-publication-clause-observations-1.0.1. Text SHA-256: ca3081691cd1239b38a8d1eefb6d4a27680c9c7abe740da87fd88b08ce9c8784. Source manifest: f29d1f421e416f71f71db108fb2179938b970e51d78f03cd085519d1c8570d75.
Official source · 2006-08-09
Publication text
This is the complete recorded text of this dated publication.
Current legal effect is unknown. Aircraft applicability, installed configuration and compliance require separate evidence. PDF/text agreement has not been evaluated.
Read the complete official publication text
[Federal Register Volume 71, Number 153 (Wednesday, August 9, 2006)]
[Rules and Regulations]
[Pages 45364-45367]
From the Federal Register Online via the Government Publishing Office [www.gpo.gov]
[FR Doc No: E6-12829]
-----------------------------------------------------------------------
DEPARTMENT OF TRANSPORTATION
Federal Aviation Administration
14 CFR Part 39
[Docket No. FAA-2006-25536; Directorate Identifier 2006-NM-158-AD;
Amendment 39-14707; AD 2006-16-07]
RIN 2120-AA64
Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional
Jet Series 100 & 440) Airplanes
AGENCY: Federal Aviation Administration (FAA), Department of
Transportation (DOT).
ACTION: Final rule; request for comments.
-----------------------------------------------------------------------
SUMMARY: The FAA is adopting a new airworthiness directive (AD) for
certain Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440)
airplanes. This AD requires inspecting contactors 1K4XD, 2K4XD, and
K4XA to determine the type of terminal base plate, and applying sealant
on the terminal base plates, if necessary. This AD results from
incidents of short circuit failures of certain alternating current (AC)
contactors located in the avionics bay. We are issuing this AD to
prevent short circuit failures of certain AC contactors, which could
result in arcing and consequent smoke or fire.
[[Page 45365]]
DATES: This AD becomes effective August 9, 2006.
The Director of the Federal Register approved the incorporation by
reference of a certain publication listed in the AD as of August 9,
2006.
We must receive comments on this AD by October 10, 2006.
ADDRESSES: Use one of the following addresses to submit comments on
this AD.
<bullet> DOT Docket Web site: Go to http://dms.dot.gov and follow
the instructions for sending your comments electronically.
<bullet> Government-wide rulemaking Web site: Go to http://www.regulations.gov and follow the instructions for sending your
comments electronically.
<bullet> Mail: Docket Management Facility; U.S. Department of
Transportation, 400 Seventh Street, SW., Nassif Building, Room PL-401,
Washington, DC 20590.
<bullet> Fax: (202) 493-2251.
<bullet> Hand Delivery: Room PL-401 on the plaza level of the
Nassif Building, 400 Seventh Street SW., Washington, DC, between 9 a.m.
and 5 p.m., Monday through Friday, except Federal holidays.
Contact Bombardier, Inc., Canadair, Aerospace Group, P.O. Box 6087,
Station Centre-ville, Montreal, Quebec H3C 3G9, Canada, for service
information identified in this AD.
FOR FURTHER INFORMATION CONTACT: Wing Chan, Aerospace Engineer, Systems
and Flight Test Branch, ANE-172, FAA, New York Aircraft Certification
Office, 1600 Stewart Avenue, suite 410, Westbury, New York 11590;
telephone (516) 228-7311; fax (516) 794-5531.
SUPPLEMENTARY INFORMATION:
Discussion
Transport Canada Civil Aviation (TCCA), which is the airworthiness
authority for Canada, notified us that an unsafe condition may exist on
certain Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440)
airplanes. TCCA advises that there have been eight incidents of short
circuit failures of Tyco Hartman alternating current (AC) contactors
1K4XD and K4XA, located in the avionics bay on Model CL-600-2B19
(Regional Jet Series 100 & 440) airplanes. All of the failed AC
contactors had a terminal base plate made from Ultem 2200 material. In
several cases, arcing, which initiated due to the presence of
contaminants between the power studs, resulted in a fire, which
continued until power to the AC contactor was interrupted, either by
the wire being burned through or by the generator falling off-line.
Short circuit failures of AC contactors, if not prevented, could result
in arcing, which could result in smoke or fire.
Relevant Service Information
Bombardier has issued Service Bulletin 601R-24-122, Revision A,
dated July 13, 2006. The service bulletin describes procedures for
inspecting contactors 1K4XD, 2K4XD, and K4XA to determine which
contactors have an Ultem 2200 terminal base plate (the plate is made
from a black molded thermal plastic material), and applying RTV 732
sealant or RTV 3145 sealant, if necessary. TCCA mandated the service
bulletin and issued Canadian airworthiness directive CF-2006-17, dated
July 11, 2006, to ensure the continued airworthiness of these airplanes
in Canada.
FAA's Determination and Requirements of this AD
This airplane model is manufactured in Canada and is type
certificated for operation in the United States under the provisions of
section 21.29 of the Federal Aviation Regulations (14 CFR 21.29) and
the applicable bilateral airworthiness agreement. As described in this
bilateral airworthiness agreement, TCCA has kept the FAA informed of
the situation described above. We have examined TCCA's findings,
evaluated all pertinent information, and determined that we need to
issue an AD for products of this type design that are certificated for
operation in the United States.
Therefore, we are issuing this AD to prevent short circuit failures
of certain AC contactors, which could result in arcing and consequent
smoke or fire. This AD requires accomplishing the actions specified in
the service information described previously, except as discussed under
``Difference Among the AD, Service Bulletin, and Canadian Airworthiness
Directive.''
Difference Among the AD, Service Bulletin, and Canadian Airworthiness
Directive
The service bulletin specifies to determine if the terminal base
plate is made of a black molded thermal plastic material. The Canadian
airworthiness directive specifies doing a visual inspection of the
contactors to determine which contactors have an Ultem 2200 terminal
base plate. However, operators should note that we have determined that
the inspection should be described as a ``general visual inspection''
to determine which contactors have an Ultem 2200 terminal base plate
(i.e., a plate made from a black molded thermal plastic material). Note
1 has been included in this AD to define this type of inspection.
Interim Action
We consider this AD interim action. If final action is later
identified, we may consider further rulemaking then.
FAA's Determination of the Effective Date
An unsafe condition exists that requires the immediate adoption of
this AD; therefore, providing notice and opportunity for public comment
before the AD is issued is impracticable, and good cause exists to make
this AD effective in less than 30 days. The compliance time for doing
the required actions is within 800 flight hours or four months. Based
on the large number of affected U.S. registered airplanes (739) and the
amount of time required to accomplish the required actions, including
corrective actions (27 hours), we consider that this compliance time is
necessary to avoid unnecessarily disrupting flight schedules.
Comments Invited
This AD is a final rule that involves requirements that affect
flight safety and was not preceded by notice and an opportunity for
public comment; however, we invite you to submit any relevant written
data, views, or arguments regarding this AD. Send your comments to an
address listed in the ADDRESSES section. Include ``Docket No. FAA-2006-
25536; Directorate Identifier 2006-NM-158-AD'' at the beginning of your
comments. We specifically invite comments on the overall regulatory,
economic, environmental, and energy aspects of the AD that might
suggest a need to modify it.
We will post all comments we receive, without change, to http://dms.dot.gov, including any personal information you provide. We will
also post a report summarizing each substantive verbal contact with FAA
personnel concerning this AD. Using the search function of that Web
site, anyone can find and read the comments in any of our dockets,
including the name of the individual who sent the comment (or signed
the comment on behalf of an association, business, labor union, etc.).
You may review the DOT's complete Privacy Act Statement in the Federal
Register published on April 11, 2000 (65 FR 19477-78), or you may visit
http://dms.dot.gov.
Examining the Docket
You may examine the AD docket on the Internet at http://dms.dot.gov, or in person at the Docket Management Facility office
between 9 a.m. and 5
[[Page 45366]]
p.m., Monday through Friday, except Federal holidays. The Docket
Management Facility office (telephone (800) 647-5227) is located on the
plaza level of the Nassif Building at the DOT street address stated in
the ADDRESSES section. Comments will be available in the AD docket
shortly after the Docket Management System receives them.
Authority for This Rulemaking
Title 49 of the United States Code specifies the FAA's authority to
issue rules on aviation safety. Subtitle I, Section 106, describes the
authority of the FAA Administrator. Subtitle VII, Aviation Programs,
describes in more detail the scope of the Agency's authority.
We are issuing this rulemaking under the authority described in
Subtitle VII, Part A, Subpart III, Section 44701, ``General
requirements.'' Under that section, Congress charges the FAA with
promoting safe flight of civil aircraft in air commerce by prescribing
regulations for practices, methods, and procedures the Administrator
finds necessary for safety in air commerce. This regulation is within
the scope of that authority because it addresses an unsafe condition
that is likely to exist or develop on products identified in this
rulemaking action.
Regulatory Findings
We have determined that this AD will not have federalism
implications under Executive Order 13132. This AD will not have a
substantial direct effect on the States, on the relationship between
the national government and the States, or on the distribution of power
and responsibilities among the various levels of government.
For the reasons discussed above, I certify that the regulation:
1. Is not a ``significant regulatory action'' under Executive Order
12866;
2. Is not a ``significant rule'' under the DOT Regulatory Policies
and Procedures (44 FR 11034, February 26, 1979); and
3. Will not have a significant economic impact, positive or
negative, on a substantial number of small entities under the criteria
of the Regulatory Flexibility Act.
We prepared a regulatory evaluation of the estimated costs to
comply with this AD and placed it in the AD docket. See the ADDRESSES
section for a location to examine the regulatory evaluation.
List of Subjects in 14 CFR Part 39
Air transportation, Aircraft, Aviation safety, Incorporation by
reference, Safety.
Adoption of the Amendment
0
Accordingly, under the authority delegated to me by the Administrator,
the FAA amends 14 CFR part 39 as follows:
PART 39--AIRWORTHINESS DIRECTIVES
0
1. The authority citation for part 39 continues to read as follows:
Authority: 49 U.S.C. 106(g), 40113, 44701.
Sec. 39.13 [Amended]
0
2. The Federal Aviation Administration (FAA) amends Sec. 39.13 by
adding the following new airworthiness directive (AD):
2006-16-07 Bombardier, Inc. (Formerly Canadair): Amendment 39-14707.
Docket No. FAA-2006-25536; Directorate Identifier 2006-NM-158-AD.
Effective Date
(a) This AD becomes effective August 9, 2006.
Affected ADs
(b) None.
Applicability
(c) This AD applies to Bombardier Model CL-600-2B19 (Regional
Jet Series 100 & 440) airplanes, certificated in any category,
serial numbers 7003 through 7990 inclusive and 8000 and subsequent.
Unsafe Condition
(d) This AD results from incidents of short circuit failures of
certain alternating current (AC) contactors located in the avionics
bay. We are issuing this AD to prevent short circuit failures of
certain AC contactors, which could result in arcing and consequent
smoke or fire.
Compliance
(e) You are responsible for having the actions required by this
AD performed within the compliance times specified, unless the
actions have already been done.
Inspection and Corrective Action
(f) Within 800 flight hours or four months after the effective
date of this AD, whichever occurs first: Do a general visual
inspection of AC service bus contactors 1K4XD and 2K4XD, part number
(P/N) D-18ZZA, and the utility bus contactor K4XA, P/N D-7GRZ, to
determine which contactors have an Ultem 2200 terminal base plate
(i.e., the plate is made from a black molded thermal plastic
material), and apply RTV sealant to the terminal base plate, as
applicable, by doing all the actions specified in the Accomplishment
Instructions of Bombardier Service Bulletin 601R-24-122, Revision A,
dated July 13, 2006. Do all applicable applications of sealant
before further flight.
Note 1: For the purposes of this AD, a general visual inspection
is: ``A visual examination of an interior or exterior area,
installation, or assembly to detect obvious damage, failure, or
irregularity. This level of inspection is made from within touching
distance unless otherwise specified. A mirror may be necessary to
ensure visual access to all surfaces in the inspection area. This
level of inspection is made under normally available lighting
conditions such as daylight, hangar lighting, flashlight, or
droplight and may require removal or opening of access panels or
doors. Stands, ladders, or platforms may be required to gain
proximity to the area being checked.''
Previous Actions Accomplished According to Other Service Information
(g) Actions accomplished before the effective date of this AD in
accordance with Bombardier Drawing Number K601R50180, dated June 2,
2006; or Bombardier Service Bulletin 601R-24-122, dated June 27,
2006; are considered acceptable for compliance with the actions
specified in paragraph (f) of this AD.
Parts Installation
(h) As of the effective date of this AD, no person may install
AC contactor 1K4XD, 2K4XD, or K4XA, having an Ultem 2200 terminal
base plate, on any airplane, unless RTV sealant has been applied to
the terminal base plate in accordance with Bombardier Service
Bulletin 601R-24-122, Revision A, dated July 13, 2006.
Alternative Methods of Compliance (AMOCs)
(i)(1) The Manager, New York Aircraft Certification Office, FAA,
has the authority to approve AMOCs for this AD, if requested in
accordance with the procedures found in 14 CFR 39.19.
(2) Before using any AMOC approved in accordance with Sec.
39.19 on any airplane to which the AMOC applies, notify the
appropriate principal inspector in the FAA Flight Standards
Certificate Holding District Office.
Related Information
(j) Canadian airworthiness directive CF-2006-17, dated July 11,
2006, also addresses the subject of this AD.
Material Incorporated by Reference
(k) You must use Bombardier Service Bulletin 601R-24-122,
Revision A, dated July 13, 2006, to perform the actions that are
required by this AD, unless the AD specifies otherwise. The Director
of the Federal Register approved the incorporation by reference of
this document in accordance with 5 U.S.C. 552(a) and 1 CFR part 51.
Contact Bombardier, Inc., Canadair, Aerospace Group, P.O. Box 6087,
Station Centre-ville, Montreal, Quebec H3C 3G9, Canada, for a copy
of this service information. You may review copies at the Docket
Management Facility, U.S. Department of Transportation, 400 Seventh
Street SW., Room PL-401, Nassif Building, Washington, DC; on the
Internet at http://dms.dot.gov; or at the National Archives and
Records Administration (NARA). For information on the availability
of this material at the NARA, call (202) 741-6030, or go to http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html.
[[Page 45367]]
Issued in Renton, Washington, on July 31, 2006.
Ali Bahrami,
Manager, Transport Airplane Directorate, Aircraft Certification
Service.
[FR Doc. E6-12829 Filed 8-8-06; 8:45 am]
BILLING CODE 4910-13-P
Why this text is shown
The complete text was extracted from the official GovInfo HTML edition for this publication. Acquired 2026-10-09T03:44:39.567516+00:00. Text extraction preserves the recorded source wording; it does not determine current requirements.
Open the captured official edition
- Source SHA-256
- 1a1dde65d4c9a6df9bae6563a897ebb249ff1961a80c60f6160c6054fea59959
- Text SHA-256
- ca3081691cd1239b38a8d1eefb6d4a27680c9c7abe740da87fd88b08ce9c8784
Return to the full metadata catalog · Search complete publication text · Explore retained publication text and evidence
Coverage and limits
These are dated publication metadata, recorded clauses and literal source observations. Word, model-label, header and reference matches do not establish current legal effect, manufacturer/model identity, aircraft applicability, installed configuration or compliance.
The collection uses 33 explicit annual source snapshots. Source captures and operative-text qualifications have separate states. Missing information remains unknown.